February 27, 2017

How To Stop Water Hammer

What is Water Hammer?

Water hammer is shock wave produced by the sudden stoppage or reduction of a fluid flow. This can cause sudden rises in pressure and damage instrumentation. In tank level measurement applications, high pressures can be generated by the sudden closure of a valve on an outlet line. Although it might seem to be a consistent flow, the water inside pipes tumbles as it moves through.

Continue Reading →

February 13, 2017

Why Choose Rogowski Coils?

Many electricians and contractors are moving towards using Rogowski Coils because of the time saved during installation and the reduced shipping costs for high amperage requirements. Because of the size, weight and flexibility of a Rogowski Coil, installers can save significant time and labor because of the ease of surrounding conductors of all sizes. However, what most people don’t realize is that Rogowski Coils have many technical advantages over standard split-core or “donut” CT’s which can help improve monitoring energy in different applications.

Continue Reading →

February 09, 2017

The AHR 2017 Experience

Thank you to all who visited us at Booth C1452 in the Building Automation and Controls section of the AHR Expo this year in Las Vegas, Nevada! We enjoyed seeing both new and familar faces! The world's largest HVACR event was anything but boring and we think the 60,000 attendees would have to agree.

Continue Reading →

January 16, 2017

How to use a single Power Supply to power pressure transducers

When installing a pressure transducer system, selecting a power supply may not be one of the first things that comes to your mind. Since a single power supply can be used to power multiple pressure transducers, many regard it as a non-vital task. Nonetheless, it is essential to have the proper configurations between the power source and devices in order for all components to communicate properly and to avoid receiving inaccurate data. Here are some of the best practices we found for using a single power supply to power multiple devices.

Continue Reading →

January 05, 2017

What is the Difference Between Unidirectional and Bidirectional Pressure Transducers?

Unidirectional Pressure Transducers

Unidirectional pressure transducers measure between zero and a positive pressure. The diaphragm of the sensor should only move in one direction and will produce a positive voltage or milliamp output.

Continue Reading →

January 03, 2017

How to Troubleshoot a Pressure Transducer

Pressure transducers today are more rugged and reliable than ever. Made of stainless steel construction, they provide abundant overpressure protection, improved total error band, and offer negligible orientation and vibration effects. They are ideal for long-term use even in harsh environments of extreme temperature, humidity, and vibration.

Continue Reading →

December 29, 2016

Can A Room Pressure Monitor Help Me Save Energy?

Monitoring and controlling room pressure in laboratory and healthcare settings can do more than just ensure directional airflow (positive or negative pressure rooms). Proper room pressure also contributes to saving energy. Overpressure or under-pressure scenarios mean that airflow, or even temperature control, are not optimal.

Continue Reading →

December 26, 2016

Why is Pressure Sensor Accuracy Important?

The accuracy of differential pressure transducers has greatly improved to provide better solutions for demanding applications. This article discusses why accuracy is an important consideration when selecting a pressure transducer for low-differential, critical pressure applications.

Continue Reading →

December 05, 2016

Capacitance & Inductive Pressure Sensors

Capacitive Transducers

Setra’s capacitive pressure transducers are expertly designed adaptations of a simple, durable and fundamentally stable device...the electrical capacitor. In a typical Setra configuration, a compact housing contains two closely spaced, parallel, electrically isolated metallic surfaces, one of which is essentially a diaphragm capable of slight flexing under pressure. 

Continue Reading →

November 24, 2016

The Importance of Maintaining Building Humidity

While it is important to maintain proper relative humidity levels in office buildings for worker comfort and productivity, it is also just as important to maintain proper levels in factories, production facilities and art galleries to protect industrial, commercial and artistic products.

Continue Reading →