Tank Level and Wastewater

Liquid-level sensors provide analysis of tank contents, helping measure, monitor, and control the liquids in tanks. Depending on the type of tank and its use, there are a variety of methods to monitor tanks from both inside and outside the vessel. Capacitance liquid-level sensors provide intensely accurate measurements for many industries, including:

Continue Reading →

March 02, 2017

Considerations For Properly Measuring Tank Level

Whether you are looking for a solution to solve a tank level measurement issue to a building or trying to monitor a process tank within your factory, the proper tank level is extremely important to the success of your project. There are countless applications across many industries that with a few simple steps can ensure that you can meet the needs of your project.

Continue Reading →

February 27, 2017

How To Stop Water Hammer

What is Water Hammer?

Water hammer is shock wave produced by the sudden stoppage or reduction of a fluid flow. This can cause sudden rises in pressure and damage instrumentation. In tank level measurement applications, high pressures can be generated by the sudden closure of a valve on an outlet line. Although it might seem to be a consistent flow, the water inside pipes tumbles as it moves through.

Continue Reading →

January 19, 2017

5 Considerations When Selecting a Pressure Transducer for Industrial Applications

1. Pressure

The first and most important consideration is pressure. A number of questions must be answered to ensure the correct transducer is selected. What is the pressure range that the transducer will measure? What is the maximum pressure the transducer will encounter? What is the potential for over pressure in the system?

Continue Reading →

January 03, 2017

How to Troubleshoot a Pressure Transducer

Pressure transducers today are more rugged and reliable than ever. Made of stainless steel construction, they provide abundant overpressure protection, improved total error band, and offer negligible orientation and vibration effects. They are ideal for long-term use even in harsh environments of extreme temperature, humidity, and vibration.

Continue Reading →

December 26, 2016

Why is Pressure Sensor Accuracy Important?

The accuracy of differential pressure transducers has greatly improved to provide better solutions for demanding applications. This article discusses why accuracy is an important consideration when selecting a pressure transducer for low-differential, critical pressure applications.

Continue Reading →

December 01, 2016

Does Your Product Fall Under New RoHS2 Restrictions?

Newly Added Restricted Products Under RoHS2 Affects Manufacturing

In 2013, RoHS2 was created by the European Union legislation, nearly a decade after the original RoHS (Restriction of Hazardous Substances Directive) was implemented.  RoHS2 is merely an evolution of RoHS1 that provides greater clarity on the legal scope of products that should adhere to the hazardous material guidelines. The combination of

Continue Reading →

November 02, 2016

What is Total Error Band & How do You Calculate It?

Total Error Band (TEB) is a measurement of worst case error; it is the most comprehensive and concise measurement of a sensors true accuracy over a compensated temperature range.  TEB is extremely important to know when trying to determine how well a sensor will work within a particular design system. By calculating TEB you'll be able to understand the different possibilities for error. Formulating TEB can be tricky if you don't have the right inputs readily available. 

Continue Reading →

October 31, 2016

Make Halloween Spookier with Pressure Transducers

Happy Halloween From Setra

Have you ever wanted to build your own Haunted House or Spooky Trail?

I'm sure we've all thought about it one time or another. You know what I'm talking about. Places like amusement parks, fairs, or even a homemade one that your “Halloween Crazed” neighbors down the street built themselves. But how do they work?

Continue Reading →

October 20, 2016

What is Absolute Pressure?

Absolute pressure is measured relative to a full vacuum (0 PSIA = 14.7 PSIV).  The electrical output of an absolute pressure transducer is 0 VDC at 0 PSIA and full scale output (typically 5 VDC) at full scale pressure (in PSIA).  PSIA (pounds per square inch absolute) is a unit of pressure measured relative to a full vacuum.  A vacuum can refer to any pressure between 0 PSIA and 14.7 PSIA.

Continue Reading →