title: How To Select an Intrinsically Safe Pressure Transducer
description: Learn what to look for when selecting intrinsically safe pressure transducers.
image: http://www.setra.com/hubfs/bigstock-Stainless-Steel-6551529.jpg
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

# How To Select an Intrinsically Safe Pressure Transducer

#### by [Tom Lish](https://www.setra.com/blog/author/tom-lish)

- [Tweet](https://twitter.com/share)

There are 5 things you should know when selecting [intrinsically safe pressure transducers](https://www.setra.com/products/pressure/model-31is-intrinsically-safe-atex-iecex-certified-pressure-transducer-0) there are a number of things to look for.

1. Be assured that the pressure transducer has been significantly modified for intrinsically safe applications — the printed circuit board has been simplified to use low voltage and current, capacitors and inductors have been minimized, etc. Intrinsically safe pressure transducers typically operate on low voltage DC (VDC) and consume less than 1 watt of power. If a capacitance type pressure transducer is desired for an application, it also can be certified as intrinsically safe.

2. Be sure to select small sputtered thin film units, that are less than 1" in diameter, and made of all stainless steel wetted [![intrinsically safe pressure transducer](http://www.setra.com/hs-fs/hubfs/bigstock-Stainless-Steel-6551529.jpg?width=263&name=bigstock-Stainless-Steel-6551529.jpg "intrinsically safe pressure transducer")](https://www.setra.com/blog/applications-that-are-intrinsically-safe)parts. They should come with a broad selection of electrical and pressure connections, and a wide choice of electrical outputs ready for installation. Heavy-duty applications will feature a thicker diaphragm and a pressure resistor designed to withstand the rigors of cavitation and extreme pressure spikes.

3. State-of-the-art intrinsically safe pressure transducers use the well-proven Wheatstone bridge principle. Molecular layers are sputtered onto a 17-4 PH stainless steel diaphragm and the circuit is etched to provide excellent resistor definition and uniformity. Sputtered thin film technology allows the design of simple, highly accurate and compact strain gauges deposited onto the back of the sensing diaphragm, which is in direct contact with the media. Find a design that provides ±0.25 percent full-scale accuracy over its full temperature range. In addition, it should have long-term stability of better than ±0.1 percent full scale per year, enhanced sensitivity, and virtually no drift.

4. Construction should be all welded stainless steel with no internal elastomers, RTV silicon adhesive sealant or epoxies. The unit should offer a wide pressure range, such as from 75 PSI to 32,000 PSI. It should have no oil that could cause thermal instability and/or leakage. Verify the unit is CE and RoHS compliant.

5. Engineers may consider using a [capacitance based pressure transducer](https://www.setra.com/blog/introduction-capacitance-based-pressure-transducers/2012/10/10) design to minimize orientation and vibration issues by using a stretched stainless steel diaphragm that is not fluid filled. The only gravity effect it has is the weight of the diaphragm, which is not insignificant, but very small and is easily compensated for in the field.

**[CLICK HERE](https://www.setra.com/general-industrial) to see Setra's industrial products.**

 Topics: [General Industrial OEM](https://www.setra.com/blog/topic/general-industrial-oem), [Process/Mfg Tank Level](https://www.setra.com/blog/topic/process-mfg-tank-level), [Test and Measurement](https://www.setra.com/blog/topic/test-and-measurement), [General Industrial](https://www.setra.com/blog/topic/general-industrial), [Oil and Gas](https://www.setra.com/blog/topic/oil-and-gas)

### Recent Posts

### Posts by Topic

- [Critical Environments (184)](https://www.setra.com/blog/topic/critical-environments)
- [HVAC/R (180)](https://www.setra.com/blog/topic/hvac-r)
- [General Industrial (153)](https://www.setra.com/blog/topic/general-industrial)
- [Building Automation (135)](https://www.setra.com/blog/topic/building-automation)
- [General Industrial OEM (92)](https://www.setra.com/blog/topic/general-industrial-oem)
- [Energy Management (85)](https://www.setra.com/blog/topic/energy-management)
- [Test and Measurement (66)](https://www.setra.com/blog/topic/test-and-measurement)
- [HVAC/R OEM (60)](https://www.setra.com/blog/topic/hvac-r-oem)
- [Barometric (44)](https://www.setra.com/blog/topic/barometric)
- [Alternative Fuels (42)](https://www.setra.com/blog/topic/alternative-fuels)
- [Medical (41)](https://www.setra.com/blog/topic/medical)
- [Process/Mfg Tank Level (40)](https://www.setra.com/blog/topic/process-mfg-tank-level)
- [Water and Wastewater (39)](https://www.setra.com/blog/topic/water-and-wastewater)
- [OHV (38)](https://www.setra.com/blog/topic/ohv)
- [Oil and Gas (35)](https://www.setra.com/blog/topic/oil-and-gas)
- [Industrial Vacuum (29)](https://www.setra.com/blog/topic/industrial-vacuum)
- [Calibration (25)](https://www.setra.com/blog/topic/calibration)
- [Semiconductor (25)](https://www.setra.com/blog/topic/semiconductor)
- [Particle Counting (20)](https://www.setra.com/blog/topic/particle-counting)
- [Cleanroom Monitoring (18)](https://www.setra.com/blog/topic/cleanroom-monitoring)
- [Room Pressure Monitoring (17)](https://www.setra.com/blog/topic/room-pressure-monitoring)
- [Trade Show (12)](https://www.setra.com/blog/topic/trade-show)
- [cleanroom environment (12)](https://www.setra.com/blog/topic/cleanroom-environment)
- [Environmental Monitoring (11)](https://www.setra.com/blog/topic/environmental-monitoring)
- [Power Meters (11)](https://www.setra.com/blog/topic/power-meters)
- [Scales (11)](https://www.setra.com/blog/topic/scales)
- [Healthcare (10)](https://www.setra.com/blog/topic/healthcare)
- [Power Monitoring (10)](https://www.setra.com/blog/topic/power-monitoring)
- [Software (9)](https://www.setra.com/blog/topic/software)
- [cleanroom monitoring systems (9)](https://www.setra.com/blog/topic/cleanroom-monitoring-systems)
- [Case Study (8)](https://www.setra.com/blog/topic/case-study)
- [critical environment technologies (8)](https://www.setra.com/blog/topic/critical-environment-technologies)
- [data centers (8)](https://www.setra.com/blog/topic/data-centers)
- [Humidity (7)](https://www.setra.com/blog/topic/humidity)
- [particle counter (6)](https://www.setra.com/blog/topic/particle-counter)
- [pressure transducers (6)](https://www.setra.com/blog/topic/pressure-transducers)
- [LITE room pressure monitor (5)](https://www.setra.com/blog/topic/lite-room-pressure-monitor)
- [hardware and software cleanroom monitoring systems (5)](https://www.setra.com/blog/topic/hardware-and-software-cleanroom-monitoring-systems)
- [setra lite (5)](https://www.setra.com/blog/topic/setra-lite)
- [Compliance (4)](https://www.setra.com/blog/topic/compliance)
- [Video (3)](https://www.setra.com/blog/topic/video)
- [hospital spaces (3)](https://www.setra.com/blog/topic/hospital-spaces)
- [FAQ & Troubleshooting (2)](https://www.setra.com/blog/topic/faq-troubleshooting)
- [Monitoring Compounding Pharmacies (2)](https://www.setra.com/blog/topic/monitoring-compounding-pharmacies)
- [Semiconductor Manufacturing (2)](https://www.setra.com/blog/topic/semiconductor-manufacturing)
- [agencies that monitor pharmacies (2)](https://www.setra.com/blog/topic/agencies-that-monitor-pharmacies)
- [energy (2)](https://www.setra.com/blog/topic/energy)
- [hvac (2)](https://www.setra.com/blog/topic/hvac)
- [laboratories (2)](https://www.setra.com/blog/topic/laboratories)
- [monitor compound pharmacy (2)](https://www.setra.com/blog/topic/monitor-compound-pharmacy)
- [protected environment (2)](https://www.setra.com/blog/topic/protected-environment)
- [regulatory compliance (2)](https://www.setra.com/blog/topic/regulatory-compliance)
- [setra lite features (2)](https://www.setra.com/blog/topic/setra-lite-features)
- [usp 797 (2)](https://www.setra.com/blog/topic/usp-797)
- [Application Note (1)](https://www.setra.com/blog/topic/application-note)
- [Current Sensors and Transducers (1)](https://www.setra.com/blog/topic/current-sensors-and-transducers)
- [Current Transformers (1)](https://www.setra.com/blog/topic/current-transformers)
- [Lithium-Ion Battery (1)](https://www.setra.com/blog/topic/lithium-ion-battery)
- [Pressure (1)](https://www.setra.com/blog/topic/pressure)
- [aerospace cleanrooms (1)](https://www.setra.com/blog/topic/aerospace-cleanrooms)
- [cems (1)](https://www.setra.com/blog/topic/cems)
- [digital transformation (1)](https://www.setra.com/blog/topic/digital-transformation)
- [ipv6 multicast (1)](https://www.setra.com/blog/topic/ipv6-multicast)
- [ipv6 multicast address (1)](https://www.setra.com/blog/topic/ipv6-multicast-address)
- [ipv6 multicast address range (1)](https://www.setra.com/blog/topic/ipv6-multicast-address-range)
- [isolation room pressure monitoring (1)](https://www.setra.com/blog/topic/isolation-room-pressure-monitoring)
- [multicast address ipv6 (1)](https://www.setra.com/blog/topic/multicast-address-ipv6)
- [multicast ipv6 (1)](https://www.setra.com/blog/topic/multicast-ipv6)
- [operating room (1)](https://www.setra.com/blog/topic/operating-room)
- [pharma 4.0 (1)](https://www.setra.com/blog/topic/pharma-4-0)
- [pressure sensor (1)](https://www.setra.com/blog/topic/pressure-sensor)
- [pressure transducer companies (1)](https://www.setra.com/blog/topic/pressure-transducer-companies)
- [semi conductor (1)](https://www.setra.com/blog/topic/semi-conductor)
- [sensors and transducers (1)](https://www.setra.com/blog/topic/sensors-and-transducers)
- [setra pressure transducers (1)](https://www.setra.com/blog/topic/setra-pressure-transducers)
- [submetering (1)](https://www.setra.com/blog/topic/submetering)
- [sustainability (1)](https://www.setra.com/blog/topic/sustainability)
- [temperature monitor (1)](https://www.setra.com/blog/topic/temperature-monitor)
- [temperature monitoring for pharmacies (1)](https://www.setra.com/blog/topic/temperature-monitoring-for-pharmacies)
- [transducers (1)](https://www.setra.com/blog/topic/transducers)
- [usp 800 (1)](https://www.setra.com/blog/topic/usp-800)
- [water (1)](https://www.setra.com/blog/topic/water)
- [what does hvac stand for (1)](https://www.setra.com/blog/topic/what-does-hvac-stand-for)
- [what is a transducer (1)](https://www.setra.com/blog/topic/what-is-a-transducer)
- [what is hvac (1)](https://www.setra.com/blog/topic/what-is-hvac)

[see all](https://www.setra.com/blog/how-to-select-an-intrinsically-safe-sensor#)

[![HVAC Catalog Cover Image 1](https://www.setra.com/hs-fs/hubfs/HVAC%20Catalog%20Cover%20Image%201.png?width=160&name=HVAC%20Catalog%20Cover%20Image%201.png "HVAC Catalog Cover Image 1")](http://setrasystems.uberflip.com/setra-systems/hvac-catalog-feb-2017)

 

**HVAC Catalog**

 

This comprehensive HVAC Product Catalog is now available online. [Download the PDF now.](http://setrasystems.uberflip.com/setra-systems/hvac-catalog-feb-2017)

 

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)