---
title: OEM Pressure Sensor | Model 3100 Thin Film Pressure Sensor | Setra Systems
description: Setra offers high-accuracy OEM pressure sensors for reliable industrial applications. Our Model 3100/3200 features thin film technology, long-term stability, reverse wiring protection, and stainless steel construction for durable OEM pressure measurement solutions.
image: https://www.setra.com/hubfs/Resized_Product_Images/Model_3100_NB.jpg
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

[Products](https://www.setra.com/products) > [Category](https://www.setra.com/category) > [Subcategory](https://www.setra.com/subcategory) > [OEM Pressure Sensor | Model 3100 Thin Film Pressure Sensor | Setra Systems](https://www.setra.com/products/pressure/model-3100-industrial-oem-pressure-transducer)

# Model 3100

![Industrial OEM Pressure Transducer: Model 3100](https://www.setra.com/hs-fs/hubfs/Resized_Product_Images/Model_3100_NB.jpg?width=244&name=Model_3100_NB.jpg "model 3100")

## Industrial OEM Pressure Transducer

[configure

](http://ecatalog.setra.com/ecatalog/configurators/3100)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![](https://www.setra.com/hubfs/product-download-icon.png)

### Data Sheet

](https://www.setra.com/hubfs/Product_Data_Sheets/Model_3100_Data_Sheet.pdf) [![](https://www.setra.com/hubfs/product-download-icon.png)

### Operating Instructions

](https://www.setra.com/hubfs/Product_Operating_Instructions/Model_3100_Operating_Instructions.pdf)

### Product Overview

The Model 3100 sputtered thin film pressure sensor is designed for OEMs who require top of the line performance, reliability and stability at an affordable price. The Model 3100 offers exceptional 0.25% FS accuracy in pressure ranges from 75 PSI to 32,000 PSI; features an all welded stainless steel constructions for a robust design and IP67 seal for moisture and humidity protection. The Model 3100 offers a variety of different outputs, pressure connectors, and electrical connectors to satisfy the most challenging application requirements. In addition, voltage units are available with a dual pressure/temperature output.

**Best in Class Price to Performance** - Strain Gauge technology provides a very linear and predictable output signals over wide temperature ranges, which enables Setra to provide an inherently stable and accurate sensor element in high volume and at low cost. The Model 3100 sensors constructed using a highly sophisticated automation process, where the sensors are manufactured in a Class 100 clean room. To ensure best in class accuracy and long term stability, each sensing element is thermally compensated to an accuracy of less than 0.005%/°C prior to leaving the clean room for final assembly. Thermally compensating the unit ensures improved accuracy and simplified conditioning electronics; while eliminating the need for calibration over elevated temperatures as a transducer.

**Unrivaled Quality** - Setra understands the importance of quality in OEM applications, which is why we are always looking for ways to improve the quality rating of the product. Over the last two years, the Model 3100 failure rate is less than 0.1%, a quality rating unmatched by the competition. The worst thing that could happen to an engineer is to shut down their work because of quality issues, Setra takes this seriously which is why we have worked hard to ensure that product improvements are made to reduce quality issues to our customers.

**Rugged Designed** - The Model 3100 compact welded stainless steel designs are constructed to protect the sensors in demanding industrial environments. The electrical connectors are tested to an environmental protection specification of IP67 and above and a robust internal design ensures that the transducers can survive high levels of vibration. A high level of EMC protection allows the transmitters to perform to the most stringent of industrial standards and all devices are RoHS compliant.

### Product Specifications

- No Oil Fill - Prevents Thermal Instability & Leakage
- Wide Choice of Pressure Ranges from 75 PSI up to 32,000 PSI
- 0.25% FS Accuracy
- Dual Temperature and Pressure Output
- Small Footprint - Less than 1in. Diameter
- Choice of Current, Voltage, or Ratiometric Outputs
- Reverse Wiring Protection
- Accuracy Specified Over Full Temperature Range
- All Welded Stainless Steel Construction

### Downloads

[Model 3100 Spec Sheet](https://www.setra.com/hubfs/Product_Data_Sheets/Model_3100_Data_Sheet.pdf)

[Model 3100 Operating Instructions](https://www.setra.com/hubfs/Product_Operating_Instructions/Model_3100_Operating_Instructions.pdf)

## Related Products

[

### Model 209

](https://www.setra.com/products/pressure/model-209-gauge-pressure-transducer) [

### Model 206

](https://www.setra.com/products/pressure/model-206-industrial-pressure-transducer) [

### Model CSC

](https://www.setra.com/products/power-monitoring/current/model-csc-split-core-current-switch)

![recent-blog-image.jpg](https://www.setra.com/hs-fs/hub/211498/file-2669502567.jpg?width=1920&name=file-2669502567.jpg "recent-blog-image.jpg")

## Featured Downloads

[![HVAC Product Catalog  This comprehensive HVAC Product Catalog is now available online. Click to  download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99)

[![Industrial Product Selection Guide  This comprehensive Industrial Sensing Product Selection Guide is now available  online. Click to download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/da9fad78-d798-4a49-98e0-352ad3a7679d.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/da9fad78-d798-4a49-98e0-352ad3a7679d)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)