Setra Blog


May 30, 2013

Best Practices for Wet-to-Wet Differential Pressure Measurements

For high line pressure, high differential pressure applications

The pressure difference across an orifice plate, filter, pump, valve, etc. can be sensed with two pressure transducers such as the Model 206. One transducer measures the high side pressure (P1) while the other measure the low side pressure (P2). Pressure media can be any liquid or gas compatible with 17-4 pH stainless steel.

Continue Reading →

May 22, 2013

Remote Pressure Sensor Applications

Why are industry leaders using remote sensors?

Wet-to-wet differential pressure transducers have undergone several significant design and technological improvements recently. The most dramatic of which is the ability to install these units with remote sensors, rather than with traditional embedded sensing elements. A contractor can now easily install remote sensors directly into the pipes while an electrician makes electrical connections between the remote sensors and the transducer via cables or conduit. For industrial applications, contractors can order plumbing-ready cable versions with up to 30 feet of cable. When the local electrical code requires conduit, typically for projects like schools or municipal buildings, contractors can order units in the conduit version.

Continue Reading →

May 15, 2013

Application Note: Current Switch Comparison

There are a variety of current switches and current transducers currently available for use in HVAC applications. Each product provides different features and benefits for that particular job. This post reviews two common types of current switches and a new technology that eliminates the risk of arc flash hazard during installation.

Continue Reading →

April 24, 2013

Differential Pressure Transducer Installation: Traditional vs Remote Sensors

Traditional vs. Remote Sensor Installation

To better understand the labor and material savings made possible by remote sensors, it is important to compare the traditional method of installing differential pressure transmitters with the new method of installing remote sensors. On a typical job using the conventional method, the mechanical contractor first installs taps with shutoff valves—usually a ball or petcock valve—in the desired locations in the mechanical piping.

Continue Reading →

April 03, 2013

Top 3 Design Considerations When Selecting an Industrial Pressure Transducer

After reviewing the top 5 product considerations (pressure, media, temperature, and environment) in which the pressure transducer will be installed, it’s time to look at transducer construction, circuit design and the pressure transducer manufacturer's supply chain.

Continue Reading →

March 20, 2013

New Technology Eliminates Arc Flash Hazard

Pre-configuration of current switches can help eliminate arc flash danger and enable faster installation

Technician wearing a PPE suit

Current switches, also known as current sensors, are used to monitor the operation of motors, pumps, fans, compressors, lights, and other equipment. Two common types of current switches currently available are fixed point and adjustable set point switches. Fixed current switches are designed with a single pre-determined set point and are beneficial because they are installed on cold circuits requiring no adjustment. 

Continue Reading →

March 06, 2013

How to Select Multi-Range Pressure Sensors

When selecting multi-range pressure sensors, there are certain things to be cautious of. Often a "one size fits all" pressure transducer is chosen for expected cost savings and inventory control; however this decision turns out to be a bad idea. Issues arise with inaccuracy and poor stability on low range applications where the range output adjustment is simply pushed too far.

Continue Reading →

February 20, 2013

Application Note: Liquid Level Measurement

Liquid Level

The pressure measured at the bottom of a liquid filled tank is proportional to both the height (head) and density of the liquid. For best results the pressure should be sensed by a pressure transmitter mounted at the lowest point possible on the tank, as shown in Figure 1.

Continue Reading →

January 30, 2013

How to Prevent Over Pressurizing Critical Spaces with Room Pressure Monitors

Openings Doors in the Operating Room

Recently, a major Boston-area hospital sought to resolve a problem in its operating rooms (OR). Nurses were complaining about how difficult it was to open the doors to the facility’s 23 operating rooms, 5 of which had just been built. They couldn’t understand why they had to pull so hard to open the doors. A veteran hospital HVAC engineering and design consultant did some investigating and recognized the problem of airborne lint on the sensors controlling OR pressurization.

Continue Reading →

December 26, 2012

Happy Holidays!

On behalf of all of us here at Setra, we'd like to wish everyone a safe and happy holiday season.

Continue Reading →