title: Model 290 | Sanitary Pressure Transducer
description: Setra's Model 290 sanitary pressure transmitter complies with 3-A sanitary standards and is designed for CIP/SIP installations, food , pharmaceutical processing, etc.
image: https://www.setra.com/hubfs/Resized_Product_Images/Model_290_NB.jpg
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

[Products](https://www.setra.com/products) > [Category](https://www.setra.com/category) > [Subcategory](https://www.setra.com/subcategory) > [Model 290 | Sanitary Pressure Transducer](https://www.setra.com/products/pressure/model-290-sanitary-pressure-transducer)

# Model 290

![Sanitary pressure Transducer: Model 290](https://www.setra.com/hs-fs/hubfs/Resized_Product_Images/Model_290_NB.jpg?width=244&name=Model_290_NB.jpg "290")

## Sanitary Pressure Transducer

[configure

](http://ecatalog.setra.com/ecatalog/configurators/290)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![](https://www.setra.com/hubfs/product-download-icon.png)

### Data Sheet

](https://www.setra.com/hubfs/Product_Data_Sheets/Setra_Model_290_Data_Sheet.pdf) [![](https://www.setra.com/hubfs/product-download-icon.png)

### Operating Instructions

](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_290_Operating_Instructions.pdf)

### Product Overview

The Model 290 is Setra’s highest accuracy solution for measuring gauge and compound pressure ranges in sanitary processing applications. Unlike competitive transducers which use an oil filled design, the 316L stainless steel sensor is designed to operate without the need for an intermediary liquid within the sensor. The design of the 290 negates clamp effect making installation and service faster and easier than the competition. Its small footprint and accuracy (±0.2% FS) covers a wide range of pressure ranges that meet both 3A certification and withstand CIP/SIP environmental conditions, making it ideal for a variety of applications.

**Robust Non-Liquid Filled Sensor **- The Model 290 sanitary pressure transducer uses an air variable capacitance sensor. This sensor design eliminates chance of “product” contamination, position effect and thermal transients when compared to liquid filled sensors. The diaphragm is able to withstand pressure down to full vacuum for worry  free operation during tank and piping evacuation cycles.

**Negligible Clamping Effect** - The process interface of the 290 negates the effect of clamping pressure on the output signal of the sensor. This design allows the sensor to be delivered in a small footprint with the diaphragm closely mounted to the process media which ensures the most accurate measurements.

**Flexibility in Application** - The Model 290 is the most versatile sanitary pressure transducer on the market. Its design allows full scale tank level measurements as low as 27.7” WC with an accuracy of 0.027” and up to 1000 PSI for process lines. The 316L wetted components meet 3A requirements for food and beverage industry applications; its optional 20Ra finish make it the ideal solution for use in Biotech applications.

### Product Specifications

- High Accuracy: ±0.2% FS
- Robust Non-Liquid Filled Capacitive Sensor
- Negligible Clamping Effect for Easy Installation
- Designed for Clean-In-Place (CIP) and Sterilize-In-Place SIP) Installations
- 1.5" and 2" Tri-Clover Fittings
- High Overpressure Protection
- Not Sensitive to Thermal Shock

### Downloads

[Model 290 Data Sheet](https://www.setra.com/hubfs/Product_Data_Sheets/Setra_Model_290_Data_Sheet.pdf)

[Model 290 Operating Instructions](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_290_Operating_Instructions.pdf)

[Model 290 Case Study: Vaporized Hydrogen Peroxide Sterilizers](https://www.setra.com/hs-fs/hub/211498/file-2484508409.pdf)

## Related Products

[

### Model 206

](https://www.setra.com/products/pressure/model-206-industrial-pressure-transducer) [

### Model 256

](https://www.setra.com/products/pressure/model-256-gauge-pressure-transducer)

![recent-blog-image.jpg](https://www.setra.com/hs-fs/hub/211498/file-2669502567.jpg?width=1920&name=file-2669502567.jpg "recent-blog-image.jpg")

## Featured Downloads

[![HVAC Product Catalog  This comprehensive HVAC Product Catalog is now available online. Click to  download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99)

[![Industrial Product Selection Guide  This comprehensive Industrial Sensing Product Selection Guide is now available  online. Click to download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/da9fad78-d798-4a49-98e0-352ad3a7679d.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/da9fad78-d798-4a49-98e0-352ad3a7679d)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)