Ultra-High
Purity & Vacuum Pressure Transducers

|
Model
212FT
True Flow-Through Pressure Transducer
True flow-through design for accurate in-line
pressure measurement of liquids or gases. A 1/4"
tube electropolished to 7Ra (10 max) finish
eliminates potential particle and moisture
entrapment. Available in gauge or compound
pressure ranges from 100 to 3000 psig, and in
absolute pressure ranges from 30 to 3000 psia. |
|
Model
217
Downmount Pressure Transducer for Modular "Block"
Gas Sticks
Designed for modular "Block" gas sticks
and panels. The Model 217 is a down-mount ("C"
Seal) pressure transducer with a small swept
sensor chamber for easy purgeability. All wetted
parts are VAR316L SS electropolished to 7Ra (10
max.) finsih. Available in gauge, absolute or
compound ranges from 25 psig to 3000 psig. Also
available in BAR ranges. |
|
Model
223
1" Dia. Flow-Through Pressure
Transducer
The Model 223's one inch diameter and flow
through design make it an ideal fit for most
ultra-high purity applications. This pressure
transducer is available with a variety of
pressure fittings including tube stub and Swivel
Face Seals, and choice of 4 pin Bayonet connector
or 6 ft. Multiconductor Cable for electrical
termination. The Model 223 has a rotatable cover
for side access to zero and span potentiometers. |
|
Model
224:
1.3" Dia. Flow-Through Pressure
Transducer
The Model 224 flow-through pressure transducer is
available with a variety of pressure fittings
including tube stub and Swivel Face Seals, and
choice of 4 pin Bayonet connector, 9 pin or 15
pin D-sub connectors, or 6 ft. Multiconductor
Cable for electrical termination. The Model 224
has top access to zero and span potentiometers. |
|
Model GCT225:
Single-Ended Low Cavity Volume Pressure
Transducer
Superior stability, sturdy design, low
cavity volume and low price, make this pressure
transducer a wise choice for high purity
applications. Available with choice of 5 VDC, 10 VDC, or 4 to 20 mA output. |
| |
|
|
|
Model
227
Ultra-High Purity Pressure Transducer - 1-1/8" C-Seal
Downmount
The Model 227 is designed with a space-saving 1 1/8"
C-Seal downmount interfacing base for high density, modular
block gas sticks and panels required for today's 300 mm tools.
Available with choice of 5 VDC, 10 VDC, or 4-20 mA ouput and ±0.25%
Full Scale or ±1.0% of Reading
accuracy.
|
| |
|
| |
|
|
Model
327
A 1-1/8 inch Micro Display
Designed for in-line installation between the power supply and
the pressure transducer, the Model 327 has a rotatable face
for 360° viewing. A low power consumption device, the Model
327 is calibrated to convert the transducer's 0 to 5 VDC, 0 to
10 VDC, or 4 to 20 mA output to a viewable 3-1/2 digit
display. A choice of electrical connector combinations are
available. The Model 327 interfaces with Setra's Model 217,
223, 224, and 227. |
|
|
|
HEATED
700 Series Vacuum Pressure Transducer
Models 764/769/774
These pressure transducers offer integral heated sensors
and electronics, temperature controlled to your choice
of 45°C, 100°C,
or 123°C. Designed to
safeguard against process contamination and improve the
integrity of your process, these pressure transducers exhibit
exceptional performance. These units offer an accuracy
of ±15% of Reading with a
resolution of 0.005% of Full scale in pressure ranges as low as
100 mTorr up to 1000 Torr.
|
| |
|
|
|
Model 730 CVG:
(Capacitance Vacuum Gauge)
This low cost, compact vacuum gauge is designed to be used
with pressure media compatible with Inconel.® The accuracy of this transducer is
assured with a wide compensated operating temperature of 0 to
+50°C and exceptional temperature
coefficients of ± 0.005% FS/°C at Zero and ± 0.027% of
Rdg/°C at span. |
|
Model
760 Vactron™ Series:
Capacitance Manometer - Absolute Pressure
Transducer
This low cost capacitance manometer offers
excellent zero stability and barometric
insensitivity. Designed for accurate and
repeatable vacuum measurement, Setra's Vactron™
Model 760 capacitance manometer has a 0 to 5 VDC
or 0 to 10 VDC output that is linear with
pressure and independent of gas composition. |
|
Model
CWS 321:
Gas Cylinder Weighing Scale
The Model CWS 321 Weighing Scale is designed to
weigh gas cylinders to within 0.10% accuracy,
reducing gas replacement costs and shutdown time.
Its compressed pivot design results in a low
profile (less than 1 inch) scale, ideal for easy
gas bottle replacement. The multiple strain gauge
design eliminates off-center-loading errors. High
resistance strain gauges, combined with an
additional RFI shield, produce lower
susceptibility to output noise and RFI error. |
|