Room
Pressure Monitor: The SRPM room pressure monitor is
designed for critical low differential pressure applications
that require stringent pressure monitoring and alarming. True
differential pressure is measured and displayed with a
resolution of 0.0001" W.C. The SRPM is a complete system that
includes a convenient backlit RGB LCD display with an intuitive
graphic user interface for pressure, security, calibration, and
alarm setup. |
 |
Micro-Cal™ Model 869 Ultra-Low
Pressure Generating and Documenting Calibrator: The
Micro-Cal Model 869 ultra-low-pressure calibrator utilizes
NASA's low pressure generating technology, achieving +/-0.0002
in.W.C. low pressure regulation - micro in. of W.C. per step
resolution. Calibration can be performed in as little as 5
minutes per unit, saving the user time and service/installation
costs. |
 |
Model
260: New Multi-Sense Model 260 - One Size
Fits All - Customer friendly features such as user selectable
pressure ranges, selectable analog outputs, a standard LCD and
AC/DC excitation on voltage output operations. At a standard
accuracy of 1% FS, this unit is the only multi-range transducer
to provide fixed range performance for all selectable ranges.
(Available without an LCD Display.) |
|
|
|
Model 264:
Setra's versatile low differential pressure
transducers are widely used in the accurate
measurement of pressures and flows for proper
building pressurization and air flow control.
Optional accuracies of ±0.4% FS and ±0.25% FS
are available as well as the standard ±1.0% FS
accuracy. Pressure ranges as low as ±0.1"WC
up to 100"WC are standard, with10 PSI overpressure on all ranges. |
|
Model
265: At ±1.0% Full Scale accuracy (±0.4%,
±0.25% FS optional), Setra's Model 265 provides
superior positive and negative pressure sensing
required for high efficiency, air-control systems.
An optional snap-on conduit enclosure, molded
from high impact Lexan®, is avaialble. |
|
Model 267:
(Available with optional LCD display.) - These
units sense gauge and differential pressure and
are offered with a high level 5 VDC or 10 VDC
output as well as a 4-20 mA output. The Model 267 is available with an optional LCD display for
convenient viewing of pressure reading. |
|
|
The
Model
267 is now available with an 8" static pressure probe for duct
mounting. The
probe is available as an option on the Model 267.
Installation is quick and easy by mounting the unit directly
onto the duct. The 0.25" diameter pressure probe
is made of sturdy extruded aluminum and is designed with
baffles to prevent any velocity pressure errors.
|
| |
|
|
Model
267MR: Up to 6 field selectable pressure
ranges (bi-directional and unidirectional) in
each unit. The simple flip of a dipswitch enables
the user to easily field calibrate the unit with
minimal effort. These units sense gauge and
differential pressure and are offered with a
field selectable high level 5 VDC or 10 VDC
output as well as a 4-20 mA output. |
 |
Model
269: Designed for high performance applications such as
those found in critical medical and pharmaceutical environments.
This unit is offered in a din rail or base mount version and
features easy to access pressure ports and electrical
connections. Pressure ranges are available in ranges as
low as 0.1 inW.C. up to 10 in. W.C full scale. with choice of
±0.25%, ±0.50% or ±1.0% full scale accuracy. In
addition, this unit can be configured with an optional visual
display for local viewing and 2:1 range turndown. |
| |
|
|
|
Model
230 w/3-Valve Manifold:
The 3-valve manifold is rugged, lightweight and compact,
weighing less than 2.5 pounds and measuring 7.05"Wide x
6.25"High. Its all brass body, brass pipe fittings,
copper tubing and plastic valves are ideal for high line
pressures of 250 psi. The3-valve manifold eliminates the
possibility of exceeding the pressure rating of the
transducer. When combined with our Model 230 Wet-to-Wet
Differential Pressure Transducer, the 3-valve manifold’s
one-piece, machined brass body construction guarantees a
leak-free system and minimizes external pipe connections. |
| |
|
| |
|
| |
|

|
Model 230:
This wet to wet differential pressure transducer provides a
high output without compromising your budget. Unlike fluid
filled sensors that can rupture, the Model 230's wetted parts
are all stainless steel. Unidirectional and bi-directional
ranges are available from ±1 to 100 psid, and choice of 0 to
5 VDC or 0 to 10 VDC, or 4 to 20 mA output. |
|
Model 231 Multi-Sense,
Wet-to-Wet, Differential Pressure Transducer: The Model 231
"all in one" design provides users with field accessible
ranging, choice of output and field zeroing. Choose from three
configurable pressure transducers offering 8 switch selectable
pressure ranges from ± 5 psid up 50 psid, ±10 up to 100 psid or
±25 up to 250 psid, and choice of 0-5 VDC, 1-5 VDC, 0-10 VDC or
4 to 20 mA output in each transducer. |
|
Model 209/C209
OEM: Priced aggressively, these transducers
meet the performance requirements of
refrigeration systems. The stainless steel/Valox
housing provides a rugged, lightweight package. A
variety of pressure ranges are available: gauge,
sealed gage, and vacuum. |
|
Model 206/C206/207/C207
OEM: Known for their rugged construction and
reliability, Setra's Model 206 and 207 pressure
transducers and transmitters exhibit resistance
to shock, vibration, temperature and EMI/RFI.
These transducers are available in full scale
pressure ranges from 25 psig to 10,000 psig. |
|
Model 239/C239:
Designed to measure low pressures, the Model 239/C239
is available in unidirectional and bi-directional
ranges as low as ±0.25"WC. These
transducers are ideally suited to a variety of
applications such as HVAC Control, Medical
Instrumentation, Energy Management, Leak
Detection, Clean Rooms, and Environmental Testing.
|
|
Model 280E/C280E:
Affordability, rugged packaging, and an accuracy
of 0.11% full scale (.073% FS, optional) combine
to make these transducers an excellent choice for
the most demanding applications. Available in gauge, absolute and vacuum pressure ranges. |
|
Model 3100
and 3200 Series High Pressure/OEM
Pressure Transduce: Designed for OEM installations,
the Model 3100 standard duty is compact, measuring less than 1 inch in
diameter, and offers exceptional 0.25% Full Scale accuracy in
pressure ranges from 75 psi up to 32,000 psi. Modifications to
this unit are not necessary because of the wide range of
outputs, pressure connectors, and electrical connectors
available. In addition, voltage units are available with a dual
pressure/temperature output.
The Model 3200 Heavy Duty pressure transducer offers the same
features as the Model 3100 but is resistant to pressure spikes
with maximum over- pressure protection of 3 x full scale on
pressure ranges from 75 psi up to 10,000 psi Full Scale. Pressure
ranges up to14,500 psi over-pressures are 2.5 x full scale and
pressure ranges up to 26,000 psi over-pressures are 1.7 x full
scale.Model 3100 and 3200 meet CE, EMC, and UL standards
and are fully RoHS compliant.
|



|
Fuel
Cell Pressure Transducers:
Setra has been providing pressure
transducers to enhance fuel cell performance for the past
decade. The Setra 209, 225
and 230
offer stainless steel construction and high reliability in the
low ranges required for today's fuel cell applications. Read
more about the 209... |
|