Applications
- High Accuracy General Purpose
- R & D Test and Measurement
- Vacuum Systems
- Dynamometers
- Engine Test Cells
|
| Model 204D Specifications
|
| Full Scale Pressure Output
|
- Unidirectional:
- 5 VDC
- Bi-directional:
- ±2.5 VDC
|
| Zero Pressure Output
|
0 VDC |
Accuracy
(RSS Method)
|
±0.11% Full Scale (±10, ±25, ±50 psid [Unidirectional and Bi-directional])
±0.22% Full Scale (±100, ±250, ±500 psid [Bi-directional])
±0.14% Full Scale (10000 psid) |
| Type of Pressure
|
Differential |
| Pressure Ranges
|
- Unidirectional:
- 0 to 25, 50, 100, 250, 500, 1000, 3000, 5000, 10000 psid
- Bi-directional:
- 0 to ±10, ±25, ±50, ±100, ±250, ±500 psid
|
| Thermal Effects
|
- Compensated Range °F (°C):
- 30 to 150 (-1 to 65)
- %FS/100°F(100°C)max.zero:
- ±1.0 (±1.8)
- %FS/100°F(100°C)max.span:
- ±1.0 (±1.8)
|
| Media
|
- High Pressure Port:
- Gas or liquids compatible with 17-4PH stainless steel.
- Low Pressure Port:
- Clean dry air or non-corrosive gases (1000 psig max). (Hydrogen not recommended for use with 17-4PH stainless steel.)
|
Click here for data sheet: Model
204D
* Specifications subject to change without notice. If you don't see what you need here, please contact us.
|
| |
|
©1998 Setra Systems, Inc. All rights reserved. All names and logos are trademarks. All other names, logos, and trademarks are property of their respective owners.
Web site design by DreamLight Incorporated:
DreamLight.com |