Model 540 (w/SS
wetted parts)
Model 542 (w/Inconel® wetted parts)
High Performance
General Purpose, Weatherproof, and Immersible Pressure Transducers
|
|
Applications
- Off-Highway
- Natural Gas Equipment
- Test & Measurement
- Aerospace
- Power Plants
- Heating, Ventilating & Air-Conditioning
- Refrigeration
- Robotics
|
| Model
540/542 Specifications
|
| Electrical Output Millivolts
|
Bar Ranges
30 mV ±1% Span
2.5 Bar (30 psi) w/Inconel®
25 mV ±1% Span
PSI Ranges
25 to 33 mV Span
|
| Excitation
|
10 VDC Regulated (15 VDC max.) |
Accuracy
(RSS Method)
|
±0.1% Full Scale or ±0.8% Full Scale |
| Type of Pressure
|
Gauge
Sealed Gauge
Absolute
Differential (up to 300 psid) |
| Pressure Ranges
|
0 to 15, 30, 60, 100,150, 300, 500, 1000,
1500, 3000, 4000, 6000, 9000, 10,000 psig
1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 400, 600, 690 bar |
| Thermal Effects
|
Accuracy ±0.1% Full Scale:
Compensated Range °F (°C):
-65 to +250 (-54 to +120)
%FS/100°F(100°C)max.zero:
0.6 (1.2)
%FS/100°F(100°C)max.span:
0.6 (1.2)
Accuracy ±0.08% Full Scale:
Compensated Range °F (°C):
-65 to +250 (-54 to +120)
%FS/100°F(100°C) max.zero:
0.3 (0.6)
%FS/100°F(100°C) max.span:
0.3 (0.6)
|
| Media
|
Gases or liquids compatible with 17-4PH stainless
steel or Inconel® (Hydrogen not recommended for use with 17-4PH stainless steel) |
| Options
|
Seawater Version
Extra Lightning Protection |
Click here for data sheet:
Model 540
* Specifications subject to change without notice. If you don't see what you need here, please contact us.
|
| |
|
©1998 Setra Systems, Inc. All rights reserved. All names and logos are trademarks. All other names, logos, and trademarks are property of their respective owners.
Web site design by DreamLight Incorporated:
DreamLight.com |