Applications
- Weather Data Systems
- Laser Interferometers
- Altimeter Setting Indicators
- Transfer Pressure Standard
- Engine Test Cells
|
| Model
270 Specifications |
| Full Scale Pressure
Output |
5.0 VDC |
| Zero Pressure Output
|
0 VDC |
Accuracy
(RSS Method) |
±0.05% Full Scale |
| Type of Pressure
|
Absolute
Gage
Barometric |
| Pressure Ranges
|
0 to 10, 20, 50, 100 psia
0 to 5, 10, 20, 50, 100 psig
600 to 1100 hPa/mb
800 to 1100 hPa/mb |
| Thermal Effects
|
- Compensated Range °F (°C):
- 30 to 120 (-1 to 49)
- %FS/100°F(100°C)max.zero:
- ±0.2 (±0.36) hPa/mb
- %FS/100°F(100°C)max.span:
- ±0.2 (±0.36) hPa/mb
- %FS/100°F(100°C)max.zero:
- ±0.1 (±0.18) other ranges
- %FS/100°F(100°C)max.span:
- ±0.1 (±0.18) other ranges
|
| Media |
Non-condensing air or gas
compatible with aluminum, alumina ceramics, gold,
fluorocarbon elastomer sealant and Buna-N O-Ring |
Click here
for data sheet Model 270
* Specifications subject to change
without notice. If you don't see what you need here,
please contact us.
|