| PSI To Engineering Units |
| 1 PSI |
= |
0.068046A (atmosphere) |
| 1 PSI |
= |
0.068947b (bars) |
| 1 PSI |
= |
5.17149 cmHg (centimetres of mercury) |
| 1 PSI |
= |
70.308 cmH20 (centimetres of water) |
| 1 PSI |
= |
0.68947 db (decibars) |
| 1 PSI |
= |
68947.6 dyne/cm2 (dynes per square centimetre) |
| 1 PSI |
= |
2.3067 ft H20 (feet of water) |
| 1 PSI |
= |
70.306 g/cm2 (grams per square centimetre) |
| 1 PSI |
= |
2.0360 in Hg @ 0° C (inches of mercury) |
| 1 PSI |
= |
27.680 in H20 @ 4° C (inches in water) |
| 1 PSI |
= |
0.0000689476 kb (kilobars) |
| 1 PSI |
= |
6.89476 kN/m2 (kilonewtons per square metre) |
| 1 PSI |
= |
703.069 kg/m2 (kilograms per square metre) |
| 1 PSI |
= |
0.000703070 kg/mm2 (kilograms per square millimetre) |
| 1 PSI |
= |
0.0703070 kg/cm2 (kilograms per square millimetre) |
| 1 PSI |
= |
6.89476 kPa (kilopascals) |
| 1 PSI |
= |
0.001 kip/in2 (ksi) (kips per square inch) |
| 1 PSI |
= |
0.00689476 MPa (megapascals) |
| 1 PSI |
= |
68.947 mb (millibars) |
| 1 PSI |
= |
68947 Mb (microbars) |
| 1 PSI |
= |
0.70309 mH20 (metres of water) |
| 1 PSI |
= |
51714.9 MHg (microns of mercury) |
| 1 PSI |
= |
51.7149 mmHg (millimetres of mercury) |
| 1 PSI |
= |
6894.76 N/m2 (newtons per square metre) |
| 1 PSI |
= |
0.689476 n/cm2 (newtons per square centimetre) |
| 1 PSI |
= |
16.000 oz/in2 (ounces per square inch) |
| 1 PSI |
= |
2304.00 oz/ft2 (ounces per square foot) |
| 1 PSI |
= |
6894.76 Pa (pascals) |
| 1 PSI |
= |
144.00 lb/ft2 (pounds per square foot) |
| 1 PSI |
= |
51.7149 T (torrs) |
| 1 PSI |
= |
0.072000 ton/ft2 (tons per square foot) |
| 1 PSI |
= |
0.00050000 ton/in2 (tons per square inch) |
| Engineering Units To PSI |
| 1 A (atmosphere) |
= |
14.6960 PSI |
| 1 b (bar) |
= |
14.5039 PSI |
| 1 cmHg (centimetre of mercury) |
= |
0.193368 PSI |
| 1 cmH20 (centimetre of water) |
= |
0.014223 PSI |
| 1 db (decibar) |
= |
1.4504 PSI |
| 1 dyne/cm2 (dyne per square centimetre) |
= |
0.000014504 PSI |
| 1 ft H20 (foot of water) |
= |
0.43352 PSI |
| 1 g/cm2 (gram per square centimetre) |
= |
0.014224 PSI |
| 1 inHg @ 0° C (inch of mercury) |
= |
0.491159 PSI |
| 1 inH20 @ 4° C (inch of water) |
= |
0.036127 PSI |
| 1 kb (kilobar) |
= |
14503.8 PSI |
| 1 kN/m2 (kilonewton per square metre) |
= |
0.145038 PSI |
| 1 kg/m2 (kilogram per square metre) |
= |
0.0014223 PSI |
| 1 kg/mm2 (kilogram per square millimetre) |
= |
1422.33 PSI |
| 1 kg/cm2 (kilogram per square millimetre) |
= |
14.2235 PSI |
| 1 kPa (kilopascal) |
= |
0.145038 PSI |
| 1 kip/in2 (ksi) |
= |
1000 PSI |
| 1 MPa (megapascal) |
= |
145.038 PSI |
| 1 mb (millibar) |
= |
0.014504 PSI |
| 1 Mb (microbar) |
= |
0.000014504 PSI |
| 1 mH20 (metre of water) |
= |
1.42229 PSI |
| 1 MHg (micron of mercury) |
= |
0.0000193368 PSI |
| 1 mmHg (millimetre of mercury) |
= |
0.0193368 PSI |
| 1 N/m2 (newton per square metre) |
= |
0.000145038 PSI |
| 1 n/cm2 (newton per square centimetre) |
= |
1.45038 PSI |
| 1 oz/in2 (ounce per square inch) |
= |
0.062500 PSI |
| 1 oz/ft2 (ounce per square foot) |
= |
0.000434028 PSI |
| 1 Pa (pascal) |
= |
0.000145038 PSI |
| 1 lb/ft2 (pound per square foot) |
= |
0.00694444 PSI |
| 1 T (torr) |
= |
0.0193368 PSI |