---
title: Remote Airborne Particle Counters (5000 Series) | Setra Systems
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

[Products](https://www.setra.com/products#all) > [Particle Counting](https://www.setra.com/products#particle-counting)

Remote Airborne Particle Counter - 5000 Series

Now the SPC 5000 Series is available with **BACnet connectivity **to help meet all your automation system integration needs.

The 5000 Series Remote Particle Counters are the most feature-advanced remote particle counters available.

Integration is easy into a building automation and cleanroom management system via Ethernet or (optional) Wireless.

![particle-counter-badges-1.png](https://www.setra.com/hs-fs/hubfs/particle-counter-badges-1.png?width=250&name=particle-counter-badges-1.png "particle-counter-badges-1.png")

[![works with setra flex with flex icon](https://www.setra.com/hs-fs/hubfs/works%20with%20setra%20flex%20with%20flex%20icon.png?width=95&name=works%20with%20setra%20flex%20with%20flex%20icon.png)](https://www.setra.com/setra-flex) [![works with setra flex with flex icon](https://www.setra.com/hs-fs/hubfs/CEMS%20Website%20Graphics%20-%20Website%20Revamp.png?width=120&name=CEMS%20Website%20Graphics%20-%20Website%20Revamp.png)](https://www.setra.com/cems?hsLang=en)

- ![5301-5501-setra-particle-counter.jpg](https://www.setra.com/hubfs/5301-5501-setra-particle-counter.jpg "5301-5501-setra-particle-counter.jpg")

[**Request a Quote**](https://www.setra.com/request-a-quote?product_availability_interest=5000+Series+Particle+Counter&description=Please+send+me+a+quote+for+the+5000+Series+Remote+Airborne+Particle+Counter&hsLang=en)

Key Features

- Can measure between 0.3 μm to 25 μm particle sizes
- 0.1 CFM (2.83 LPM) flow rate
- Measures up to 6 channels of simultaneous data
- Large easy-to-use icon driven color touch screen display
- Connect using Ethernet, USB or (optional) Wireless 802.11 b/g, RS485 or RS232, or (optional) BACnet IP and BACnet MS/TP
- Displays and externally prints reports for ISO 14644-1, EU GMP Annex 1 and FS 209E
- Complies with ISO 21501-4 and JIS B9921 standards

Docs & Downloads

[Product Data Sheet](https://www.setra.com/hubfs/Setra_Product_Data_Sheets/SPC5000-SPC7000_Series_Data_Sheet.pdf)

[Product Operating Instructions](https://www.setra.com/hubfs/Setra_Product_Operating_Instructions/SPC5000_Series_Operating_Instruction.pdf)

[Instrument Management Software](https://www.setra.com/hubfs/Instrument%20Managment%20Software%20-%20SETRA%20User%20Manual%20v1.0%20xx.pdf)

[BACnet Gateway Operating Instructions](https://www.setra.com/hubfs/SS_SPC_BAC%5B1%5D.pdf)

[BACnet Object List Reference Library](https://www.setra.com/hubfs/PC_ObjectList_ICC_1.2%5B1%5D.xlsx)

[BACnet Object List Configuration File for Particle Counter](https://www.setra.com/hubfs/PCBacnetE_ICCv1.10%5B1%5D.icsproj)

Related Products

## Air Quality Monitor - 5000 Series

![5301-5302-AQM-thumb.jpg](https://www.setra.com/hs-fs/hubfs/5301-5302-AQM-thumb.jpg?width=250&name=5301-5302-AQM-thumb.jpg "5301-5302-AQM-thumb.jpg")

[VIEW PRODUCT](https://www.setra.com/product/particle-counting/5000-series-aqm?hsLang=en)

## Handheld Particle Counter - 8000 Series

![setra-8306-handheld-particle-counter-thumb.png](https://www.setra.com/hs-fs/hubfs/setra-8306-handheld-particle-counter-thumb.png?width=250&name=setra-8306-handheld-particle-counter-thumb.png "setra-8306-handheld-particle-counter-thumb.png")

[VIEW PRODUCT](https://www.setra.com/product/particle-counting/8000-series-handheld-particle-counter?hsLang=en)

## Particle Counter - 7000 Series

![setra-7301-7501-particle-counter-thumb.jpg](https://www.setra.com/hs-fs/hubfs/setra-7301-7501-particle-counter-thumb.jpg?width=250&name=setra-7301-7501-particle-counter-thumb.jpg "setra-7301-7501-particle-counter-thumb.jpg")

[VIEW PRODUCT](https://www.setra.com/product/particle-counting/7000-series?hsLang=en)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)