Setra CEMS™ monitors vital parameters in controlled environments, with customizable notifications and tracking calibration schedules. It can monitor differential pressure, relative humidity, particle counts, air change rates, door status, temperature, and more. Setra CEMS™ software is compatible with Setra or third-party hardware and can be commissioned with existing hardware or as a complete package. Sensor hardware communicates through SetraEDGE™ to the SetraCLOUD via LAN, Wi-Fi, or cellular network. Setra CEMS™ also generates reports on-demand or automatically, ensuring compliance with regulatory bodies.


Setra CEMS Connect allows you to track and trend both real-time and historical data over a rolling two-year period. The Setra CEMS Connect reporting tools allow you to capture and export any of that data.
Setra CEMS Connect software accepts inputs from both Setra and 3rd party sensing hardware. Regardless of if your application has existing hardware installed or if you are building a new facility, Setra CEMS Connect can receive and analyze your data.


Setra CEMS Connect offers both a tile view and a floor plan view that shows halo dots at each sensing device. This allows for real-time monitoring of conditions within your critical space. Alarm thresholds for each device are tailored to your space, displayed visually across Setra CEMS Connect, and sent via email and SMS text notifications.
Setra CEMS™ software is compatible with Setra or 3rd party hardware and can be commissioned with existing hardware or as a new, full hardware and software package. We will work closely with you to configure the best CEMS™ hardware configuration for your application. Sensor hardware data is communicated through the SetraEDGE™ to the SetraCLOUD via a LAN, WiFi or cellular network.
Setra's wireless transmitters and probes measure and record temperature, humidity, door contacts, and gases such as CO2. Communicating over Wi-Fi, our wireless transmitters have both visual and audible local alarms while remote alarms and text notifications are available through Setra’s Continuous Environmental Monitoring Software (Setra CEMS).
At the heart of our environmental monitoring solution is Setra FLEX. Setra FLEX is designed to monitor differential pressure right out of the box.
View room pressure status at a glance with Setra Lite. Easy to install and communicates to most building management systems.
The SetraEDGE™ communicates in-room sensor data to CEMS software via ethernet, WiFi or cellular.
Specially designed for HVAC, the SRH200 sensor by Setra is a cost effective, highly accurate and reliable solution for measuring relative air humidity and temperature.
Portable handheld device that detects particle sizes from 0.3um to 25um with a 0.1 CFM flow rate.
Detects particle sizes from 0.3um to 25 um with a 0.1 CFM flow rate. Continuous remote monitoring in a benchtop device with battery operation capability with user friendly touchscreen.
Detects particle sizes from 0.3um to 25 um with a 0.1 CFM flow rate. Continuous remote monitoring, available in benchtop or wall mount options with user friendly touchscreen.
Setra's Velocity Wand Sensor is designed to be highly accurate and reliable. Plug and play directly to Setra FLEX.
The SRF612 is used for wireless temperature measurement inside appliances and in ambient environments.
The SRF613 Transmitter utilizes a high accuracy digital sensor for stable measurement of humidity over many years and can be calibrated to remove small offset values.
The SRF614 (Ultra Low Temp) is used for wireless temperature measurement inside appliances like freezers, cryogenic tanks and incubators.
SRF615 (Configurable) is used for wireless measurement of user-defined parameters. Common measurement parameters for the SRF615 are temperature, humidity, and CO2. The SRF615 is used for wireless measurement inside appliances and incubators.
The SRF616 is designed to wirelessly monitor an external high accuracy PT100 probe and the ambient temperature of your storage and work areas with its integral sensor.