title: Model 526 | Submersible Pressure Transducer
description: Model 526
image: https://www.setra.com/hubfs/Resized_Product_Images/Model_526_NB.jpg
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

[Products](https://www.setra.com/products) > [Category](https://www.setra.com/category) > [Subcategory](https://www.setra.com/subcategory) > [Model 526 | Submersible Pressure Transducer](https://www.setra.com/products/pressure/model-526-submersible-pressure-transducer)

# Model 526

![Model 526](https://www.setra.com/hs-fs/hubfs/Resized_Product_Images/Model_526_NB.jpg?width=244&name=Model_526_NB.jpg "Model 526")

##   Industrial Pressure Transducer

OBSOLETE

For more information read [here.](https://www.setra.com/hubfs/Setra%20OBSOLETE%20message.pdf)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![](https://www.setra.com/hubfs/product-download-icon.png)

### Data Sheet

](https://www.setra.com/hubfs/Product_Data_Sheets/Setra_Model_526_Data_Sheet.pdf) [![](https://www.setra.com/hubfs/product-download-icon.png)

### Operating Instructions

](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_522_Operating_Instructions.pdf)

### Product Overview

Setra’s Model 526 pressure transducer is designed with a thicker diaphragm for robust industrial and submersible applications that require exceptional stability and high accuracy. Depending upon the electrical connection selected, when coupled with the Model 526 enclosure, which is fabricated in 316 SS/17-4 PH SS, this unit is rated for IP30, IP65, IP68 operation.

The Model 526’s modular design is offered in a wide choice of millivolt, voltage or current outputs over almost any pressure range, and a variety of pressure and electrical connections, enabling this unit to be custom configured for an OEM application.

Principle of Operation:  
Using the well proven Wheatstone Bridge Principle, a chemical vapor is deposited in thin layers or silicon and silicon dioxide onto a stainless steel sensor to form a very sensitive and accurate polysilicon strain gauge. The elements of the strain gauge are fused together at the atomic level, assuring the strength and integrity of the bond, which exceeds the adhesives used in common bonded strain gauge pressure sensors. A custom designed ASIC performs signal amplification and temperature compensation. This technology offers the user the option of configurable output and pressure ranges, sets the zero and span tolerance, and ensures interchangeability from unit to unit.

 

### Product Specifications

- Superior Stability Avoid Down Time
- IP30, IP65 and IP68 Rated
- ±0.25% FS Accuracy, Optional ±0.15%
- High Shock and Vibration Resistance

### Downloads

[Model 526 Data Sheet](https://www.setra.com/hubfs/Product_Data_Sheets/Setra_Model_526_Data_Sheet.pdf)

[Model 526 Operating Instructions](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_526_Operating_Instructions.pdf)

## Related Products

[

### Model 206

](https://www.setra.com/products/pressure/model-206-industrial-pressure-transducer) [

### Model 209

](https://www.setra.com/products/pressure/model-209-gauge-pressure-transducer) [

### Model 256

](https://www.setra.com/products/pressure/model-256-gauge-pressure-transducer)

![recent-blog-image.jpg](https://www.setra.com/hs-fs/hub/211498/file-2669502567.jpg?width=1920&name=file-2669502567.jpg "recent-blog-image.jpg")

## Featured Downloads

[![HVAC Product Catalog  This comprehensive HVAC Product Catalog is now available online. Click to  download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99)

[![Industrial Product Selection Guide  This comprehensive Industrial Sensing Product Selection Guide is now available  online. Click to download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/da9fad78-d798-4a49-98e0-352ad3a7679d.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/da9fad78-d798-4a49-98e0-352ad3a7679d)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)