title: Model 267 | Low Differential Pressure Sensor
description: Model 267
image: https://www.setra.com/hubfs/Resized_Product_Images/Model_267MR_NB.jpg
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

[Products](https://www.setra.com/products) > [Category](https://www.setra.com/category) > [Subcategory](https://www.setra.com/subcategory) > [Model 267 | Low Differential Pressure Sensor](https://www.setra.com/products/pressure/model-267-low-differential-pressure-transducer)

# Model 267

![267](https://www.setra.com/hs-fs/hubfs/Resized_Product_Images/Model_267MR_NB.jpg?width=244&name=Model_267MR_NB.jpg "267")

## Very Low Differential Pressure Transducer

[configure

](http://ecatalog.setra.com/ecatalog/configurators/267)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![](https://www.setra.com/hubfs/product-download-icon.png)

### Data Sheet

](https://www.setra.com/hubfs/Product_Data_Sheets/Setra_Model_267_Data_Sheet.pdf) [![](https://www.setra.com/hubfs/product-download-icon.png)

### Operating Instructions

](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_267_Operating_Instructions.pdf)

### Product Overview

Setra's Model 267 is Setra’s most highly configurable multirange low differential pressure transducer. It delivers accuracies of ±0.25%, 0.5% and ±1% FS and pressure ranges from 0.1” W.C. up to 100” W.C. The 267 is housed in a robust, NEMA 4 rated enclosure and has an optional static pressure probe reducing installation and material costs. The 267 is offered with an optional LCD display and a standard accuracy of ±0.5% making it ideal for high accuracy Pharmaceutical applications.

**Customization is Standard** - The 267, unlike most competitors, offers many mechanical and electrical options that can be integrated into existing designs.  The options 0.25" diameter pressure probe is made of sturdy extruded aluminum and is designed with baffles to prevent velocity pressure errors which saves money and reduces time on the job site.

**Robust Enclosure for Difficult Applications** - The 267 is housed in a NEMA 4 rated housing and is built to withstand harsh environments.  The 267 is available in both wall and duct mount providing the installer with flexible mounting options.  The wall mount allows the sensor to be installed anywhere, whereas the duct probe configuration is designed to maximize space efficiecny in difficult applications.

**The Setra Sensor** - The core technology of the 267 is the all stainless steel capacitive sensing element. Setra designs and manufactures all of their sensing elements resulting in full control over the process and quality of every single sensor. The welded dead-ended capacitive sensors requires minimal amplification and delivers excellent accuracy and longterm stability. Setra’s technology has been used in over 8 million installations and has the highest field acceptance rate in the industry.

![Prop 65 Notice](https://www.setra.com/hs-fs/hubfs/prop65.png?width=45&name=prop65.png) ***WARNING:** This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm (For more information go to [www.p65warnings.ca.gov](https://www.p65warnings.ca.gov))

**NOTICE:** Lead is encapsulated in the sensor glass housed inside the product.***

### Product Specifications

- 0.01” W.C. up to 100” W.C. Pressure Ranges
- Optional 3.5 Digit LCD Display w/ 0.5% FS Accuracy
- NEMA 4 Rated Housing
- PG-9, PG-13 or Conduit Electrical Termination
- Integral Static Pressure Probe
- 24 VAC or 24 VDC Excitation
- Meets CE Conformance Standards

### Downloads

[Model 267 Data Sheet](https://www.setra.com/hubfs/Product_Data_Sheets/Setra_Model_267_Data_Sheet.pdf)

[Model 267 Operating Instructions](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_267_Operating_Instructions.pdf)

## Related Products

[

### Model CTC

](https://www.setra.com/products/power-monitoring/current/model-CTC-split-core-current-transducer) [

### Model SRH

](https://www.setra.com/products/humidity/model-SRH-relative-humidity-sensor) [

### Model CSS

](https://www.setra.com/products/power-monitoring/current/model-CSS-solid-core-current-switch)

![recent-blog-image.jpg](https://www.setra.com/hs-fs/hub/211498/file-2669502567.jpg?width=1920&name=file-2669502567.jpg "recent-blog-image.jpg")

## Featured Downloads

[![HVAC Product Catalog  This comprehensive HVAC Product Catalog is now available online. Click to  download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99)

[![Industrial Product Selection Guide  This comprehensive Industrial Sensing Product Selection Guide is now available  online. Click to download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/da9fad78-d798-4a49-98e0-352ad3a7679d.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/da9fad78-d798-4a49-98e0-352ad3a7679d)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)