# Energy Management

Submetering Simplified

**Every year 30% of electricity in commercial buildings is wasted, let Setra help you find where your energy is going and how to manage it.**

[**On-Demand Power Meter Webinar**](https://www.setra.com/power-meter-webinar)

[**Explore Setra Power Meter**](https://www.setra.com/product/power-meters/setra-power-meter)

[![setra-systems-power-meters](https://www.setra.com/hs-fs/hubfs/setra-systems-power-meters.png?width=309&name=setra-systems-power-meters.png)](https://www.setra.com/product/power-meters/setra-power-meter)

**Energy Management Applications**

[![City Skyline](https://www.setra.com/hubfs/City%20Skyline%20960x540.jpg)

Real-Time Building Management

](https://www.setra.com/energy-management/building-management)

[![Energy Management Industrial Building Garage Door](https://www.setra.com/hubfs/Energy%20Management%20-%20Industrial%20Building%20Garage%20Doors%20960x540.jpg)

Measurement & Verification

](https://www.setra.com/energy-management/measurement-verification)

[![Compliance](https://www.setra.com/hubfs/Compliance%20960x540.jpg)

Compliance

](https://www.setra.com/energy-management/compliance)

[![Retail](https://www.setra.com/hubfs/Retail%20960x540.jpg)

Tenant Submetering

](https://www.setra.com/energy-management/tenant-submetering)

[![Data Center](https://www.setra.com/hubfs/Data%20Center%20960x540.jpg)

Energy Cost Allocation

](https://www.setra.com/energy-management/energy-cost-allocation)

[![LEED](https://www.setra.com/hubfs/LEED%20960x540.jpg)

Leed

](https://www.setra.com/energy-management/leed)

 

---

**How the Meter Works**

![power-meter-software](https://www.setra.com/hs-fs/hubfs/power-meter-software.jpeg?width=279&name=power-meter-software.jpeg)

**Configure**

Utilize the built-in configuration portal to easily map out what’s being measured to support any energy management strategy

![connect-power-meter](https://www.setra.com/hs-fs/hubfs/connect-power-meter.png?width=361&name=connect-power-meter.png)

**Connect**

Wire the voltage service lines, current transformers, pule I/O and communications wiring to the meter

![power-meter-collect](https://www.setra.com/hs-fs/hubfs/power-meter-collect.png?width=254&name=power-meter-collect.png)

**Collect**

Leverage the available BACnet or Modbus communications protocol to tie the meter into any existing or new EMS or BAS within the application

 

---

**Facilities Using Setra Power Meters**

Setra Power Meter is used in many different facilities to help monitor energy use, save on energy costs, aid with tenant billing, identify equipment malfunctions, and so much more. **Click on the buttons below to discover the many applications using Setra's Power Meter.**

 

---

**Selecting a Solution  
as Easy as 1 - 2 - 3**

**1**

Identify what's going to be metered

![energy-management-applications](https://www.setra.com/hs-fs/hubfs/energy-management-applications.png?width=190&name=energy-management-applications.png)

Look across the installation and identify the equipment that are to be measured to support energy strategy

Examples: Chillers, Lighting, AHU’s, Tenant Usage

**2**

Count up how many CT’s are needed

![spm-accessories](https://www.setra.com/hs-fs/hubfs/spm-accessories.png?width=296&name=spm-accessories.png)

Match the CT amperage to the breaker feeding the load or use Patrol Flex Coils (up to 1500A)

Single-Phase Service = 1CT  
Split-Phase Service = 2 CT’s  
Three Phase Service= 3 CT’s

**3**

Select Meter Part Number

![setra-systems-power-meters](https://www.setra.com/hs-fs/hubfs/setra-systems-power-meters.png?width=125&name=setra-systems-power-meters.png)

Take the CT count and select the meter with the right number by matching the CT’s with available inputs

SPM03EDN = 3 CT inputs  
SPM12EDN = 12 CT inputs  
SPM48EDN = 48 CT inputs

**Looking for guidance? Let us help you get started.**

[**On-Demand Power Meter Webinar**](https://www.setra.com/power-meter-webinar)

[**Contact Setra for More Info**](https://www.setra.com/contact-us?description=I+want+to+learn+more+about+the+Setra+Power+Meter)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)