Gage Pressure: Pressure measured relative to ambient atmospheric pressure. Referred to as pounds per square inch.

Absolute Pressure: Pressure measured relative to high vacuum. Referred to as pounds per square inch (absolute) or psia.

Vacuum: Vacuum measured relative to ambient atmospheric pressure. Referred to as pounds per square inch (vacuum) or psiv.

Differential Pressure: Pressure measured relative to a reference pressure. Referred to as pounds per square inch (differential) or psid.

Pressure Transducer: Provides a linear D.C. voltage output proportional to applied pressure.

Pressure Transmitter: Provides a linear current output proportional to applied pressure.

Proof Pressure: The maximum pressure that may be applied without changing performance beyond specifications.

Burst Pressure: The maximum pressure that may be applied without physical damage to the sensing element.

Accuracy: Combined error of linearity, hysteresis and repeatability. (Setra uses the root sum of the squares (RSS) method).

Linearity: The maximum deviation of any calibration point on a specified straight line, during any one calibration cycle. (Setra uses the best straight line method).

Hysteresis: The maximum difference in output, at any measured value within the specified range, when the value is approached first when increasing and then decreasing pressure.

Repeatability: The ability to reproduce output readings when the same pressure value is applied consecutively, under the same conditions, and in the same direction.

Excitation: The external electrical voltage and/or current applied to a transducer for its proper operation.

Ambient Conditions: The conditions (pressure, temperature, etc.) of the medium surrounding the case of the transducer.

Response Time: The length of time required for the output to rise to a specified percentage of its final value as a result of a step change in pressure.

Thermal Error: The maximum change in output, at any pressure value within the specified range, when the temperature is changed from room temperature to specified temperature extremes.

Thermal Zero Shift: The zero shift due to changes of the ambient temperature from room temperature to the specified limits of the operating temperature range.

   
top of page  

|PREVIOUS| |INDEX| |NEXT|

|Division Profile| |Products| |Installation Instructions| |Technology|
|Application Notes| |News Releases| |Articles| |Trade Shows| |Sales Offices|

|Site Map| |About Us| |Contact Setra| |Employment|

|Home Page|

   
  159 Swanson Road, Boxborough, MA 01719-1304
Tel (978) 263-1400 · Toll Free (800) 257-3872
     
   

©1998 Setra Systems, Inc. All rights reserved. All names and logos are trademarks. All other names, logos, and trademarks are property of their respective owners.

Web site design by DreamLight Incorporated: DreamLight.com