Corrosion Resistance Table

This corrosion guide is applicable to all Setra Systems, Inc. pressure transducers and transmitters using the one piece 17-4 pH stainless steel sensor. Models with this type of sensor are; 204, C-204, 204D (positive port only), 205-2, 206, C206, 207, C207, 209, C209, 280E, and C280E. In using these tables it should be understood that these are results of laboratory tests and are indicative only of the conditions under which they are run, and may be considered as a basis for recommendation, but not for guarantee.

Legend:    A - Excellent
    B - Good
    C - Fair
    D - Not Suitable

Corrosive Media % Conc. Temp. °F 17-4 pH
Stainless Steel
Acetaldehyde 100 70 A
Acetic Acid (aerated) 100 70 A
Acetic Anhydride 100 70 B
Acetone 100 70 A
Acetylene   70 A
Acid Mine Water   70 B
Alcohol, Ethyl   70 B
Amines   70 A
Ammonia All 70 A
Ammonium Chloride 10 70 B
Aniline 100 70 B
Barium Chloride 30 70 B
Beer     A
Benzene 100 70 B
Benzoic Acid 10 70 B
Borax 5 70 A
Boric Acid 10 70 A
Butane 100 70 A
Butyl Acetate   70 B
Butyl Chloride 100 70 A
Calcium Chloride 20 70 C
Calcium Hydroxide 10 70 B
Carbolic Acid   Boil. B
Carbon Dioxide 100 70 A
Carbon Monoxide   400 A
Carbon Tetrachloride   70 B
Carbon Tetrachloride   Boil. C
Carbonic Acid Sat. 70 B
Chloric Acid   70 D
Chloroform   70 A
Citric Acid 5 70 A
Copper Carbonate Sat. 70 A
Copper Nitrate 5 70 A
Creosote 100 Hot B
Dibutylphthalate 100 70 B
Diethylene Glycol 100 70 A
Diphenyl Oxide 100 85 B
Ethanolamine 100 70 A
Ether 100 70 A
Ethyl Acetate 100 70 B
Ethyl Alcohol 100 70 B
Ethyl Chloride 100 70 A
Ethyl Ether 100 70 B
Ethylene Glycol   70 A
Ferric Hydroxide   70 A
Ferric Sulfate 10 70 B
Fluorine dry 70 B
Formaldehyde   70 B
Formic Acid 5 150 B
Freon dry   A
Freon wet   C
Fruit Juices   70 A
Fuel Oil   Hot A
Furfural   70 B
Gasoline - refined   70 A
Gelatine     A
Glucose     B
Glycerine   70 A
Hydrocarbons   70 A
Hydrochloric Acid Conc. Boil. D
Hydrofloric Acid Conc. 70 D
Hydrogen Peroxide   70 A
Hydrogen Sulfide dry 70 A
Iodine dry 70 D
Iodoform   70 A
Isopropanol 100 70 B
Kerosene   70 A
Ketchup   70 B
Lacquers   Hot B
Lactic Acid 50 70 B
Lithium   300 A
Lithium Chloride 30 200 B
Lye (caustic)   70 B
Lysol   70 C
Magnesium Chloride 5 70 B
Magnesium Hydroxide   70 B
Magnesium Sulfate   70 B
Malic Acid Conc. 70 B
Methallyamine 100 70 B
Methyl Alcohol 100 70 B
Milk   70 A
Monoethanolamine 100 200 B
Naptha   70 B
Nickel Sulfate 10 200 B
Nitric Acid 50 70 A
Nitrous Acid 5 70 B
Oils (crude)   Hot B
Oleic Acid   70 B
Oleum   70 C
Oxalic Acid 10 70 B
Oxygen   70 A
Palmitic Acid   70 B
Paraffin   Hot A
Phenol   Boil. B
Phosphoric Acid 5 70 B
Potassium Carbonate 40 200 B
Potassium Hydroxide 50 Boil. B
Propane     B
Propylene Glycol 100 70 B
Pyridine 100 70 B
Quinine Sulfate dry 70 B
Rosin Molten   A
Salicylic Acid   70 B
Sea Water   70 B
Sewage   70 B
Silver Nitrate   70 B
Soaps   70 B
Sodium Acetate 10 70 B
Sodium Bicarbonate   70 B
Sodium Chloride 20 70 B
Sodium Hydroxide 50 Boil. B
Sodium Sulfite 5 70 B
Steam   600 A
Stearic Acid   70 B
Sulphur Dioxide dry 500 B
Sulfuric Acid 1 70 B
Sulfuric Acid 50 70 D
Tannic Acid   70 B
Trichloroethylene dry 70 B
Turpentine   70 A
Varnish   70 A
Vinegar   70 A
Water     A
Whiskey & Wine   70 A
Xylene 100 200 A
Zinc Chloride 5 70 C
Zinc Sulfate 5 70 B

   
top of page  

|PREVIOUS| |INDEX| |NEXT|

|Division Profile| |Products| |Installation Instructions| |Technology|
|Application Notes| |News Releases| |Articles| |Trade Shows| |Sales Offices|

|Site Map| |About Us| |Contact Setra| |Employment|

|Home Page|

   
  159 Swanson Road, Boxborough, MA 01719-1304
Tel (978) 263-1400 · Toll Free (800) 257-3872
     
   

©1998 Setra Systems, Inc. All rights reserved. All names and logos are trademarks. All other names, logos, and trademarks are property of their respective owners.

Web site design by DreamLight Incorporated: DreamLight.com