---
title: Model 223 | Ultra High Purity Flow Through Pressure Transducer
description: Model 223
image: https://www.setra.com/hubfs/setra-223-high-purity-flow-through-pressure-transducer.png
---

**

**

**

- Website Pages
- Products

[![Setra Systems Logo](https://www.setra.com/hubfs/setra-logo.svg "Setra Systems Logo")](https://www.setra.com/)

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Pressure Sensors](https://www.setra.com/product/pressure)**

[Differential Pressure Sensors](https://www.setra.com/product/pressure/differential)

[Absolute Pressure Sensors](https://www.setra.com/product/pressure/absolute)

[Barometric Pressure Sensors](https://www.setra.com/product/pressure/barometric)

[Compound Pressure Sensors](https://www.setra.com/product/pressure/compound)

[Gauge Pressure Sensors](https://www.setra.com/product/pressure/gauge)

[Submersible Pressure Sensors](https://www.setra.com/product/pressure/submersible)

[Vacuum Pressure Sensors](https://www.setra.com/product/pressure/vacuum)

[UHP Pressure Sensors](https://www.setra.com/product/pressure/uhp)

**[Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors)**

**[Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator)**

**[Setra CEMS™ Software](https://www.setra.com/cems)**

**[Power Meters & Accessories](https://www.setra.com/product/power-meters)**

**[Particle Counters](https://www.setra.com/product/particle-counters)**

**[Wireless Solution Systems](https://www.setra.com/wireless)**

**[Humidity/Temp Sensors](https://www.setra.com/product/humidity)**

**[Dolan-Jenner Fiber Optics](https://dolan-jenner.com)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[Building Automation](https://www.setra.com/building-automation)**

[Calibration](https://www.setra.com/building-automation/calibration-equipment)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[HVAC/R](https://www.setra.com/building-automation/hvac-applications)

**[Cleanrooms](https://www.setra.com/critical-environments)**

**[Healthcare](https://www.setra.com/critical-environments/healthcare)**

![drop-down-pressure](https://www.setra.com/hs-fs/hubfs/angle-arrow-pointing-to-right.png?width=15&name=angle-arrow-pointing-to-right.png)

**[General Industrial](https://www.setra.com/industrial)**

[Alternative Fuels](https://www.setra.com/general-industrial/vacuum-pressure-in-alternative-fuels)

[Barometric](https://www.setra.com/general-industrial/barometric-pressure-measurement-tools)

[Data Centers](https://www.setra.com/applications/data-centers/pressure-sensors)

[General Industrial OEM](https://www.setra.com/quality-approved-general-industrial-oem-solutions-setra-systems)

[HVAC/R OEM](https://www.setra.com/building-automation/hvac-r-oem-applications)

[Medical](https://www.setra.com/applications/medical-devices/pressure-sensors)

[Off-Highway Vehicles](https://www.setra.com/general-industrial/pressure-transducers-for-off-highway-vehicles)

[Oil & Gas](https://www.setra.com/general-industrial/oil-and-gas-pressure-measurement)

[Process / MFG Tank Level](https://www.setra.com/general-industrial/liquid-level-sensors)

[Test & Measurement](https://www.setra.com/general-industrial/pressure-test-and-measurement)

[Water & Wastewater](https://www.setra.com/general-industrial/liquid-level-sensors-for-water-processing)

**[Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement)**

**[Data Centers](https://www.setra.com/applications/data-centers)**

**[Energy Management](https://www.setra.com/energy-management)**

**[Fiber Optics](https://www.setra.com/fiber-optic-illuminators)**

**[Scales](https://www.setra.com/counting-scales-and-laboratory-balances)**

[![setra-nav-logo.png](https://www.setra.com/hs-fs/hubfs/setra-nav-logo.png?width=133&name=setra-nav-logo.png "setra-nav-logo.png")](https://www.setra.com/)

![Menu](https://www.setra.com/hs-fs/hubfs/moble-icon.jpg?width=30&name=moble-icon.jpg)

×

[Home](https://www.setra.com)

Markets >

[Healthcare](https://www.setra.com/critical-environments/healthcare) [Building Automation](https://www.setra.com/building-automation) [Cleanrooms](https://www.setra.com/critical-environments) [General Industrial](https://www.setra.com/industrial) [Semiconductor Manufacturing](https://www.setra.com/semiconductor-manufacturing-pressure-measurement) [Data Centers](https://www.setra.com/applications/data-centers?hsLang=en) [Energy Management](https://www.setra.com/energy-management) [Fiber Optics](https://www.setra.com/fiber-optic-illuminators) [Scales](https://www.setra.com/counting-scales-and-laboratory-balances)

Products >

[Pressure Sensors](https://www.setra.com/product/pressure) [Room Pressure Monitors](https://www.setra.com/product/room-pressure-monitors) [Particle Counters](https://www.setra.com/product/particle-counters) [Setra CEMS™ Software](https://www.setra.com/cems) [Power Meter & Accessories](https://www.setra.com/product/power-meters) [Pressure Calibrator](https://www.setra.com/product/calibration/microcal-pressure-calibrator) [Wireless Solutions Systems](https://www.setra.com/wireless) [Humidity/Temp Sensors](https://www.setra.com/product/humidity) [Dolan-Jener](https://dolan-jenner.com/) 

[OEM Solutions](https://www.setra.com/custom-solutions)

Resources >

[Blog](https://www.setra.com/blog) [Videos](https://www.setra.com/video-resources) [FAQs](https://article.setra.com/) [Compliance](https://article.setra.com/compliance-documents) [Supplier](https://www.setra.com/support/supplier) [Current Customers](https://www.setra.com/support/customer) 

[Order Online](https://ecatalog.setra.com)

Returns >

[Services & Calibration](https://www.setra.com/support/service) [New and Unused for Credit](https://www.setra.com/product-return) 

[Contact Us](https://www.setra.com/help-center)

[Products](https://www.setra.com/products) > [Category](https://www.setra.com/category) > [Subcategory](https://www.setra.com/subcategory) > [Model 223 | Ultra High Purity Flow Through Pressure Transducer](https://www.setra.com/products/pressure/model-223-ultra-high-purity-flow-through-pressure-transducer)

# Model 223

![setra-223-high-purity-flow-through-pressure-transducer](https://www.setra.com/hs-fs/hubfs/setra-223-high-purity-flow-through-pressure-transducer.png?width=800&name=setra-223-high-purity-flow-through-pressure-transducer.png)

## Ultra High Purity Flow-Through Pressure Transducer

[configure

](http://ecatalog.setra.com/ecatalog/configurators/223)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![I'd Like to be Contacted](https://no-cache.hubspot.com/cta/default/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/aa2007b8-eb62-4d10-ac93-edd9ce150b9a)

[![](https://www.setra.com/hubfs/product-download-icon.png)

### Data Sheet

](https://www.setra.com/hubfs/Setra_Product_Data_Sheets/Setra_Model_223_Data_Sheet_1.pdf) [![](https://www.setra.com/hubfs/product-download-icon.png)

### Operating Instructions

](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_223_Operating_Instructions.pdf)

### Product Overview

Setra's Model 223 ultra-high purity pressure transducer is designed for the most demanding specialty gas monitoring and control applications, where construction integrity, purity and performance cannot be sacrificed.

The 223 has a small, streamlined sensor chamber for easy purgeability. The sensor is designed to provide superior mechanical and thermal stability, especially in transient temperature conditions resulting from flowing gases. Isolation of the sensing element from the pressure fitting virtually eliminates any torque effect.

The superior mechanical and thermal stability is achieved through Setra's patented variable capacitance sensor. Its fundamentally simple design features a 316L VIM/VAR stainless steel sensor passivated to 5 Ra (7 Ra. max.) finish, which eliminates surface irregularities and provides the proper surface chemistry for corrosion resistance, and an insulated electrode plate fastened to the center of the sensor diaphragm, forming a variable capacitor. As pressure increase or decreases the capacitance changes. This change in capacitance is detected and converted to a linear analog signal by Setra’s unique electronic circuit. Various tube diameters are available with optional face seal fittings. Sturdy construction allows for trouble-free installation and high tolerance of system torsion and welding effects, providing confident installations.

Model 223 transducers are able to endure bakeout to 185°F (85°C), without affecting calibration. Every sensor is mass spectrometer helium leak tested to 1 x 10-9 ATM.CC/sec. This ultra-high purity series is based on Setra’s proven capacitive sensing technology and the highly accurate and stable voltage or current output signals are virtually EMI/RFI immune.

After manufacture and assembly, Setra’s Ultra- High Purity pressure transducers are flushed with deionized water, purged with high-purity heated nitrogen, baked, double bagged, backfilled with nitrogen and sealed, prior to shipping.

![Prop 65 Notice](https://www.setra.com/hs-fs/hubfs/prop65.png?width=45&name=prop65.png) ***WARNING:** This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm (For more information go to [www.p65warnings.ca.gov](https://www.p65warnings.ca.gov))

**NOTICE:** Lead is encapsulated in the sensor glass housed inside the product.***

### Product Specifications

- Superior Stability Avoids Downtime
- EMI/RFI Immunity Prevents False Shutdown 
- Sturdy Design Allows Trouble-Free Installations
- Minimal Torque Effect
- High Burst Pressure Ratings

### Downloads

[Model 223 Data Sheet](https://www.setra.com/hubfs/Setra_Product_Data_Sheets/Setra_Model_223_Data_Sheet_1.pdf)

[Model 223 Operating Instructions](https://www.setra.com/hubfs/Product_Operating_Instructions/Setra_Model_223_Operating_Instructions.pdf)

## Related Products

[

### Model 224

](https://www.setra.com/products/pressure/model-224-ultra-high-purity-flow-through-pressure-transducer) [

### Model 225

](https://www.setra.com/products/pressure/model-225-ultra-high-purity-pressure-transducer) [

### Model 227

](https://www.setra.com/products/pressure/model-227-ultra-high-purity-pressure-transducer)

![recent-blog-image.jpg](https://www.setra.com/hs-fs/hub/211498/file-2669502567.jpg?width=1920&name=file-2669502567.jpg "recent-blog-image.jpg")

## Featured Downloads

[![HVAC Product Catalog  This comprehensive HVAC Product Catalog is now available online. Click to  download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/0f7226d5-7c20-442d-9373-06ff8eb7de99)

[![Industrial Product Selection Guide  This comprehensive Industrial Sensing Product Selection Guide is now available  online. Click to download the PDF. Download](https://no-cache.hubspot.com/cta/default/211498/da9fad78-d798-4a49-98e0-352ad3a7679d.png)](https://cta-redirect.hubspot.com/cta/redirect/211498/da9fad78-d798-4a49-98e0-352ad3a7679d)

- [**](https://www.facebook.com/SetraSystems)
- [**](https://twitter.com/setrasystems)
- [**](https://www.youtube.com/user/SetraSystems)
- [**](https://www.linkedin.com/company/setra-systems)
- [**](https://www.instagram.com/setrasystemsinc/)

[Service & Calibration](https://www.setra.com/support/service) | [Products](https://www.setra.com/products) | [Service/RMA](https://www.setra.com/support/service) | [Supplier](https://www.setra.com/support/supplier) | [Customer](https://www.setra.com/support/customer) | [Contact Us](https://www.setra.com/contact-us) | [FAQs](https://faq.setra.com) | [About](https://www.setra.com/about) | [Careers](https://careers.fortive.com/gems-setra/) | [Request Quote](https://www.setra.com/request-a-quote) | [Blog](https://www.setra.com/blog)

 Cookie Settings

159 Swanson Road Boxborough, MA 01719 | [orders@setra.com](mailto:orders@setra.com)

[+1 (978) 263-1400

](tel:+19782631400)

Copyright © 2026 Setra Systems. All Rights Reserved. | [Terms & Conditions](https://www.setra.com/terms-and-conditions) | [Privacy Notice](https://www.setra.com/privacy-policy) | [ISO 9001:2015 Certified | ](https://www.setra.com/hubfs/ISO%20Setra%20LLC%202025.pdf)[Prop 65](https://www.setra.com/prop65) | [Patents](https://www.setra.com/patents) | [Cookies](https://www.setra.com/cookies)

[![Setra Systems Logo](https://www.setra.com/hs-fs/hubfs/setra-systems-logo_white-1.png?width=100&name=setra-systems-logo_white-1.png)](https://www.setra.com/)[![Ralliant logo](https://www.setra.com/hs-fs/hubfs/Ralliant_Logo_SingleColor_White_RGB.png?width=125&name=Ralliant_Logo_SingleColor_White_RGB.png "Setra Systems is a Ralliant Company")](https://www.ralliant.com/)