Model SRMD

Temperature and Humidity Display Panel

Email to a Friend

Customers also bought:

  • Room Pressure Monitor, Touchscreen, BACnet® option

  • Multi-Room Monitoring Station

  • Room Pressure and Condition Monitor, Flush Mount, Touchscreen, BACnet® option

 Overview
Setra's temperature and humidity display panel features a CE compliant, high visible, large 1 inch 3.5 digit LCD display and an attractive flush mounted faceplate bezel. This display panel is compatible with any temperature, humidity, CO2 sensor that has a 0 to 5 VDC or 0 to 10 VDC analog output. It clearly displays the sensor's mesurement and the reading can be easily calibrated by the user. The temperature and humidity display panel is typically used in surgical suites, isolation rooms, pharmaceutical clean rooms, animal research laboratories among many other applications. Its attractive flush mount faceplate design is wipe down capable. The temperature and humidity display are available in Red, Green, or Blue and can be ordered as a single display or a dual display. Additional bundling package is available with Setra's Relative Humidity (SRH) sensors with temperature output and comes factory calibrated for quick installation. 
Features
Features and Benefits
 
> High visible 1" LCD Display
> Flush Mounted
> Wipe Down Capable
> Available in Red, Green, or Blue
> Choose Single LCD Display or Dual LCD Display
> Mount in Standard 4-11/16 Electrical Box
> Compatible with Any Analog 0 to 5 or 0 to 10 VDC Output Sensor
 
   
Physical Description            
Flush Mount Bezel    Fire Retardent Platic UL94V-0
Bezel Dimensions
Double Display Model 5.9"H x 5.9"W                   
LCD Assembly Dimension      1.89"H x 3.78"W x 1.5"D

Shipping Weight (approx.)

10 oz (238 grams) Single Display Model
13 oz (369 grams) Dual Display Model
Mounting    Standard 4-11/16 Double Gange Electrical Box
Environmental Data
Temperature
   Operating* deg. F (deg C) 14 to +122 (-10 to +50)
   Storage deg. F (deg. C). -40 to +167 (-40 to +75)      
Operating Humidity    5 to 95% RH (Non-Condensing)
Display

Display                                      LCD   

Available in Red, Green, or Blue Backlight                                                  1" High 3.5 digit (+1999 counts)

Engineering Units Jumper Selectable deg. F, deg. C, %, PSI
Decimal Points Jumper Selectable
Electrical Data (per display)
Power Input 15-32 VDC or 24 VDC
Current Consumption 50 mA max (per display)
Analog Signal Input 0 to 5VDC or 0 to 10 VDC Jumper Selectable
Adjustments Wide Adjustable Zero and Span by 25-Turn Pots
Accuracy +/-1% FS +/- 2 Counts
Input Impedance >300K Ohms
Sampling Rate 3 Readings Per Second
Connection Screw Terminals
Certification
CE EMC Directive 2004/108/EC
 Documents and Downloads