Model 869 Expert System

Reduces cal. time by up to 90%, secure EPIC interface w/ models 269 and SRPM

Click here for product data sheet:   Model 869XP Data Sheet

Email to a Friend

Customers also bought:

  • Room Pressure Monitor, Touchscreen, BACnet® option

  • Very low differential or gauge pressure for building energy management

  • High accuracy / performance, very low differential pressure for critical environments

 Overview
The new Model 869 Expert System pressure generating and docuementing low pressure calibrator contains all of the same features as the 869 and more.  The Expert System, when combined with Setra’s 269 pressure transducers and SRPM Room Pressure Monitor, has fully automated testing and hands-off calibration which reduces calibration times to 5 minutes or less.  The 869 and 269 were specifically developed to be a full pressure transducer/ calibration solution for critical environments and HVAC applications.  This pairing ensures automated communication, testing, and calibration between the two.  This same logic was implemented in the development of the SRPM as well.  Also, the calibrator can read analog output and communicate digitally. 
Features
> Fully Automated, Hands-Off Calibration reduces calibration times by 2/3 or more

> No tube cutting or wire removal is required

> Easy-to-Use, Smart Communication Software provides transducer detection and automated calibration with Setra’s digital transducers and room pressure monitors
 
> Electropneumatic Interface Cable (EPIC) allows the 869 to simultaneously pressurize a 269 or SRPM under test and automatically transmit ID and calibration data between the two units

> Two EPIC Cable Lengths Offered: 6ft (standard) & 12ft (optional), providing easy access to units located in remote, difficult to access areas

> Easily Upgrade Original 869 - simply send in your unit and it will be returned with the installed Expert System.
This is especially convenient if performed when your 869 is in the factory for it’s annual recertification
Pressure Ranges
 
Range One:
 
0 to 5 in.WC
0 to 1 in. WC
0 to 0.25 WC
0 to 5 in. WC
0 to 2.5 in. WC
0 to 2.5 in. WC
0 to 15 in. WC
0 to +/- 0.25 in.WC
0 to +/- 0.5 in. WC
0 to +/- 1 in.WC
0 to +/- 2.5 in.WC
0 to +/- 5 in. WC
0 to +/- 15 in. WC
 
+/- 50 Pa
0 to 100 Pa
+/- 100 Pa
0 to 250 Pa
+/- 250 Pa
0 to 500 Pa
+/- 500 Pa
0 to 1000 Pa
+/- 1000 Pa
0 to 3500 Pa
+/- 3500 Pa
 
Range Two
 
0 to 5 in.WC
0 to 1 in. WC
0 to 0.25 WC
0 to 5 in. WC
0 to 2.5 in. WC
0 to 2.5 in. WC
0 to 15 in. WC
0 to +/- 0.25 in.WC
0 to +/- 0.5 in. WC
0 to +/- 1 in.WC
0 to +/- 2.5 in.WC
0 to +/- 5 in. WC
0 to +/- 15 in. WC
 
+/- 50 Pa
0 to 100 Pa
+/- 100 Pa
0 to 250 Pa
+/- 250 Pa
0 to 500 Pa
+/- 500 Pa
0 to 1000 Pa
+/- 1000 Pa
0 to 3500 Pa
+/- 3500 Pa
 
PDA
 
Includes PDA
 
User Interface
 
Standard User Interface
 
Options

269 Auto-Cal System
    • Model 242903-06
      Static Pressure Tip, same as A-302 with 6” insertion depth

      Model 299 Dri-Sense
      Pressure transducer termination enclosure, replaceable desiccating covers, NEMA 4X

      Model 242901-04
      4" straight static pressure sensor tip with flange

      Model 242902-04
      Static Pressure Tip for 1/4” metal tubing connection

      Model 242902-12
      Static Pressure Tip, same as A-301 with 12” insertion depth

      Model 242901-06
      6" straight static pressure sensor tip with flange

      Model 242902-08
      Static Pressure Tip, same as A-301 with 8” insertion depth

      Model 242902-06
      Static Pressure Tip, same as A-301 with 6” insertion depth

      Model 242903-04
      Static Pressure for 3/16” and 1/8” I.D. plastic or rubber tubing

      Model 242904
      Static pressure fitting for 1/4” metal tubing connection

      Model 242905
      Static pressure fitting for 3/16” and 1/8” I.D. plastic or rubber tubing

      Model 242901-08
      8" straight static pressure sensor tip with flange