Model 267 Buy Now / Configure

Very low differential, Optional LCD, and Static Probe

Click here for product data sheet:   Model 267 Data Sheet

Email to a Friend

Customers also bought:

 Overview
The Model 267 pressure transducer sense gauge and differential pressure and are offered with a high level 5 VDC or 10 VDC output as well as a 4-20 mA output. The Model 267 is available with an optional LCD display for convenient viewing of pressure reading.
Features
> Optional 3 1/2 Digit LCD Display with a 0.5% FS Standard Accuracy

> NEMA 4/IP65 Rated Housing

> Optional Accuracies as High as 0.25% FS

> 24 VAC or 24 VDC Excitation

> PG-9, PG13.5 or Conduit Electrical Termination

> Integral Static Pressure Probe

> Ranges as low as 0.1 in. W.C. (25 Pa)

> Meets Conformance Standards

Pressure Ranges

in. W.C.
0 to 0.1 ± 0.1
0 to 0.25 ± 0.25
0 to 0.5 ± 0.5
0 to 1 ±1
0 to 1.5 ±1.5
0 to 2.5 ± 2.5
0 to 5 ± 5
0 to 10 ±10
0 to 25 ±25
0 to 50 ±50
0 to 100

Pascals
0 to 25   ±25
0 to 50   ±50
0 to 100 ±100
0 to 250 ±250
0 to 500 ±500
0 to 1000 ±1000
0 to 2500 ±2500
0 to 4000
0 to 7000

Accuracy

±1.0%FS
 
Output

 4-20 mA
 0-5 VDC
 0-10 VDC
Excitation

Voltage:
(for 0-5 VDC Output) 9 to 30 VAC/12 to 40 VDC
(for 0-10 VDC Output) 11 to 30 VAC/13 to 40 VDC

Current:  24V (DC Only)
Units

in.WC
Pascal
Pressure Type

Differential
Bidirectional
Pressure Fitting/Elec. Termination

3/16’’ Barbed Brass
Standard Fitting
PG-13.5 Strain Relief
PG 9 Strain Relief
9 pin D-sub Connector1/2’’ Conduit Opening
 
Media
 
Typically air or similar non-conducting gases
Options
 
Display
LCD Display
No Display
 
Accuracy
Optional (w/Cal. Cert)
±0.4% FS
±0.25% FS
±1.0% FS
±0.5% FS
 
Pressure Fitting/Electrical Termination
1/4’’ NPT F, Brass
Optional Fitting
PG-9 Strain Relief
PG 13.5 Strain Relief
9 pin D-sub Connector
1/2’’ Conduit Opening
 
Static Duct Probe
Optional Fitting
PG 9 Strain Relief
PG 13.5 Strain Relief
9 pin D-Sub Connector
1/2" Conduit Opening
 
    • Model 242905
      Static pressure fitting for 3/16” and 1/8” I.D. plastic or rubber tubing

      Model 242902-12
      Static Pressure Tip, same as A-301 with 12” insertion depth

      Model 242904
      Static pressure fitting for 1/4” metal tubing connection

      Model 242902-06
      Static Pressure Tip, same as A-301 with 6” insertion depth

      Model 299 Dri-Sense
      Pressure transducer termination enclosure, replaceable desiccating covers, NEMA 4X

      Model 242903-04
      Static Pressure for 3/16” and 1/8” I.D. plastic or rubber tubing

      Model 242902-08
      Static Pressure Tip, same as A-301 with 8” insertion depth

      Model 242901-04
      4" straight static pressure sensor tip with flange

      Model 242901-08
      8" straight static pressure sensor tip with flange

      Model 242901-06
      6" straight static pressure sensor tip with flange

      Model 242902-04
      Static Pressure Tip for 1/4” metal tubing connection

      Model 242903-06
      Static Pressure Tip, same as A-302 with 6” insertion depth

 Documents and Downloads