Model 230 Buy Now / Configure

Wet-to-Wet, low differential pressure for liquids and gasses

Click here for product data sheet:   Model 230 Data Sheet

Email to a Friend

Customers also bought:

  • Multi-Range Wet-to-Wet, differential pressure for liquids and gasses

  • Gauge, Compound, and Vacuum Pressure, 1 to 10,000 PSIG, reliable, CE, RoHS compliant

  • Current switch, clamped/split core for existing installations, optional snap-on power relay

 Overview
The Model 230 wet to wet differential pressure transducer provides a high output without compromising your budget. Unlike fluid filled sensors that can rupture, the Model 230's wetted parts are all stainless steel. Unidirectional and bi-directional ranges are available from ±1 to 100 psid, and choice of 0 to 5 VDC or 0 to 10 VDC, or 4 to 20 mA output.
Features
> NEMA 4/IP65 Rating

> No Liquid Fill Diaphragm

> Available with 3-Valve Manifold Assembly Option

> Low Line Pressure Effect

> Fast Response

> Gas and Liquid Compatible

> Low Differential Ranges

and RoHS Compliant

Pressure Ranges

Unidirectional
0-1.0 PSID
0-2.0 PSID
0-5.0 PSID
0-10.0 PSID
0-25.0 PSID
0-30.0 PSID
0-50.0 PSID
0-100.0 PSID

Bidirectional
±0.5 PSID
±1.0 PSID
±2.5 PSID
±5.0 PSID
±10.0 PSID
±25.0 PSID
±50.0 PSID

 

Accuracy

±0.25% FS
 
Output

4 to 20mA
0 to 5 VDC
0 to 10 VDC
 
Excitation

Voltage: 9-30 VDC
             13-30 VDC
Current:  24V (DC Only)
 
Pressure Fitting

1/4 NPT (F)
3-Valve Manifold Assembly
5-Valve Manifold Assembly
 
Maximum Line Pressure: 250 PSIG

Bleed Screw Seals

Viton/Silicone

Media:

Gases or liquids compatible with 300 series
and 17-4PH stainless steel, and
Viton® "O" ring.
(Hydrogen not recommended for use with
17-4 PH stainless steel.)
Options

3-Valve Manifold Assembly
 
 
 
 
 
 
5-Valve Manifold Assembly

 
 
 
 
 
 
 
Bleed Screw Seals: Buna-N
Calibration Certificate
 
    • Model 242901-06
      6" straight static pressure sensor tip with flange

      Model 299 Dri-Sense
      Pressure transducer termination enclosure, replaceable desiccating covers, NEMA 4X

      Model 242901-04
      4" straight static pressure sensor tip with flange

      Model 242903-04
      Static Pressure for 3/16” and 1/8” I.D. plastic or rubber tubing

      Model 242902-06
      Static Pressure Tip, same as A-301 with 6” insertion depth

      Model 242902-08
      Static Pressure Tip, same as A-301 with 8” insertion depth

      Model 242905
      Static pressure fitting for 3/16” and 1/8” I.D. plastic or rubber tubing

      Model 242902-12
      Static Pressure Tip, same as A-301 with 12” insertion depth

      Model 242901-08
      8" straight static pressure sensor tip with flange

      Model 242904
      Static pressure fitting for 1/4” metal tubing connection

      Model 242903-06
      Static Pressure Tip, same as A-302 with 6” insertion depth

      Model 242902-04
      Static Pressure Tip for 1/4” metal tubing connection